1.  Install ductwork/flex hose completely before operating collector.

a.  Seal ductwork with silicone sealant or duct tape if leaks are found.
b.  Have dust drum in place and sealed.

2.  DO NOT operate without filter in place. Debris will cause damage to the motor!
3.  THIS UNIT IS NOT RATED FOR USE IN COMBUSTIBLE ENVIRONMENTS.
4.  This equipment incorporates parts such as switches, motors or the like that tend to produce arcs or sparks that can cause an 

explosion.

5.  To reduce the risk of Electric Shock, DO NOT use outdoors or on wet surfaces.
6.  Exhaust air should not be vented into a wall, a ceiling, or a concealed space of a building.
7.  To reduce the risk of injury from moving parts - unplug BEFORE servicing.
8.  Ensure that your dust collector is turned off and unplugged during installation.
9.  Use this equipment for dry material collection only. DO NOT use for liquid collection. 

  

WARNING

  

  

FIRE HAZARDS

  

1.  Wood shaping and cutting processes generate wood chips, shavings and dust. These materials are considered combustible. Air 

borne wood dust below 420 microns in size (0.017 of an inch) in certain concentration ranges when ignited can deflagrate (burn 

quickly). An ignition source such as a spark or ember can ignite a dust mixture resulting in an expanding flame front, which can 

cause an explosion if tightly contained. A disturbance that raises a cloud of accumulated fine dust can raise additional dust clouds, 

which can cause a series of explosions that can level an entire building. Until this type of fire has been witnessed, it is difficult to 

believe the devastation. This type of fire is rare but worth safeguarding against.

2.  The best way to avoid a wood shop fire is to keep the shop clean. A shop ankle deep in dust with layers of fine dust everywhere 

is an accident waiting to happen. A good dust collection system reduces overall fire hazards but also adds new concerns. A fire 

hazard is still present. Combustible material is now in the dust collector and storage container.

3.  The following points are worth heeding:

a.  It is the buyer’s responsibility to follow all applicable federal, state, local, OSHA, NFPA, or authorities having jurisdiction 

codes and regulations when installing and operating this dust collector.

b.  Fire Marshals may want the unit located outside of the building. If the collector is located inside the facility, controls 

such as spark detection, suppression, or explosion venting may be required.

c.  Most local jurisdictions consult or adopt NFPA (National Fire Protection Agency) codes. However, other codes may 

apply. Local codes may vary from jurisdiction to jurisdiction. 

d.  NFPA664 Code book, “Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking 

Facilities”, applies to woodworking operations that occupy areas of more than 5,000 sq. ft. or to areas where dust 

producing equipment requires an aggregate dust collection flow rate of more than 1,500 cfm (cubic feet per minute). 

This exempts some small operators from the NFPA code 664, but other codes may apply in your jurisdiction. Consult 

your local Fire Marshal for help. Additional information can be found in NFPA Code Book 664.

4.  The customer assumes the responsibility for contacting their insurance underwriter regarding specific application requirements of 

 

MAKE SURE TO READ AND UNDERSTAND THE INSTALLATION AND MAINTENANCE INSTRUCTIONS AS WELL 

AS ALL RECOMMENDED SAFETY PRACTICES.

Summary of Contents for Supercell XSK000030

Page 1: ...Rev 08 03 2021 Doc ZBM000038 Appearance may vary slightly OWNER S MANUAL Supercell High Pressure Dust Collector 30 55 Gallon XSK000030 XSK000055 U S Patent 8393050 8377160 9125535 D917806...

Page 2: ......

Page 3: ...stem Specifications 4 Wall Bracket Dimensions 5 System Dimensions with 30 Gallon Drum 6 System Dimensions with 55 Gallon Drum 7 System Contents 30 55 Gallon Drum 8 Maintenance 22 Troubleshooting 26 F...

Page 4: ...type of fire is rare but worth safeguarding against 2 The best way to avoid a wood shop fire is to keep the shop clean A shop ankle deep in dust with layers of fine dust everywhere is an accident wai...

Page 5: ...er limit of flammability Be careful not to generate sparks into the sanding dust 12 Empty dust bin and clean filter often especially when sanding 13 DO NOT overload woodworking equipment especially sa...

Page 6: ...ze 20A Recommended CircuitType HACR Sound Emission 80 dBA 10 ft CARTRIDGE FILTER Filter MediaType HEPA Certified Filter Efficiency 99 97 0 3 microns Filter Surface Area 40 sq ft SYSTEM DIMENSIONS AND...

Page 7: ...to slight variations in manufacturing Wall Bracket Dimensions 2 51 mm 2 51 mm 8 203 mm 16 406 mm 1 2 13 mm 6 152 mm 20 508 mm Floor 30 Gallon 45 13 16 mm 30 Gallon with Dolly 49 13 16 mm 55 Gallon 49...

Page 8: ...rance above the Motor Assembly to allow for its removal during filter replacement and other maintenance If you purchased the Universal Drum Dolly add an additional 4 to the height of the unit System D...

Page 9: ...n Dimensions subject to slight variations in manufacturing Allow for an additional 24 of clearance above the Motor Assembly to allow for its removal during filter replacement and other maintenance If...

Page 10: ...16 Whiz Lock Nut 4 G12 AFW516075 5 16 x 3 4 Nylon Spacer 1 G13 SMS040000 Rear Support Brace 1 ID Part number Part description Qty G14 DLX050000 5 Collared Flange 1 G15 ACB060000 3 6 Quick Release Hose...

Page 11: ...ey will hinder installation of the Rear Support Brace Cyclone Mounting Positions RIGHT FORWARD LEFT G2 G14 G17 G17A G17E G17F G17G G17B G17C G17D G18 G16 D J SHEET 1 OF 1 NAME 14Ga Galv THE INFORMATIO...

Page 12: ...gree increments so that the inlet is facing parallel or perpendicular to the wall Decide how you want your system oriented during installation to best meet your shop s needs Other positions will not w...

Page 13: ...line you have marked for the Support Brace is where the fasteners will be installed to Refer to Step 9 for more information 4 Using appropriate fasteners for the wall type you are installing your sys...

Page 14: ...ns Continued FIG 7 FIG 6 6 Lift the Wall Bracket F up and over the fasteners so that the washer is on the inside of the bracket FIG 6 7 Slide the Wall Bracket F down so that the fastener is snugly ins...

Page 15: ...the suitable mounting location of this Brace Note This hardware is not load bearing and only needs to connect the brace to the wall to add additional support to the system during operation Fasten thr...

Page 16: ...the hole closest to the wall on the upper flange of the Cyclone E FIG 11 FIG 14 G4 G3 G14 G5 E 12 Connect the Cyclone E and the 5 Collared Flange G14 to the Wall Bracket F with a Flange Gasket G3 pla...

Page 17: ...G11 as shown in FIG 12 Note Ensure that the Whiz Lock Nuts are torqued down so that the rubber washers are firmly compressed this will prevent air leaks 14 Install the three remaining Hex Head Bolts...

Page 18: ...Head Bolts G8 16 Slide the Filter Hold Down Ring B over the Filter C and the previously installed bolts G7 and secure in place using four Nylock Nuts G10 FIG 16 Note Tighten hardware so that the Filt...

Page 19: ...be on the side opposite to the pulse bar Push the hose onto the fitting so that all of barbs are covered FIG 19 Note The Motor Assembly s plastic cowling can be temporarily removed for easier access...

Page 20: ...e Wall Bracket F FIG 23 20 Carefully lift the Motor Assembly A up and over the Filter C and down onto the Cyclone s E upper flange Align the Motor Assembly so its perimeter is flush with the Cyclone s...

Page 21: ...l in the pre cut hole on the Steel Drum Lid K Assembly Instructions Continued 24 Install the Quick Disconnect Kit G17 onto the bottom section of the Drum L FIG 24 Refer to the Quick Disconnect Install...

Page 22: ...or Flex Hose Infrared Sensor Hole Window Discharge 26 Attach the Flex Hose H to the inlet on the Drum Lid K and secure it in place using a Hose Clamp G15 Loosely place a second Hose Clamp G15 onto the...

Page 23: ...IG 29 30 Connect the Supercell to your tools or ductwork using the Vacuum Pressure Rated Hose I Secure the hose in place using the Turn Key Band Clamps G20 at either end FIG 30 Installation is complet...

Page 24: ...al Direct air out and away from anyone in the area Do not use this method when any hazardous material has been vacuumed up 5 Check to make sure filter is in good condition with no torn media or cracks...

Page 25: ...our system When you are not using a bag in your drum then you must use the Round Tapered Plug G19G as noted in step 30 Cleaning out the Cyclone If the drum becomes overfilled and the cone is packed wi...

Page 26: ...ove the cowling and set aside 4 Remove the plenum plate and set aside there is no hardware securing the plenum plate it is compressed between the cowling and the motors 5 Cut the Zip Tie securing the...

Page 27: ...he notches on the hold down plate 10 Re wire the motors a There is no polarity b DO NOT tamper with the grounding wire c Keep wiring consistent the same wire from each motor should be inserted into th...

Page 28: ...r duct mastic compound as a sealant 3 Make sure everything is connected 4 Check for air leaks between collector and dust drum 5 Be sure that your filter is clean One of the three motors may have reach...

Page 29: ...ustomer is however cautioned that some common materials when cut ground or processed by machinery may become very dangerous highly toxic flammable or deflagrable and explosive The user must ensure tha...

Page 30: ...HEPA filter media Wide spaced pleated filters with non stick coating for quick and easy dust removal Unique conical shape greatly facilitates dust release during pulse cleaning CleanShop 2 5 x 25 Vac...

Page 31: ...0000 This lightweight and low profile mobile dolly fits nearly any cylindrical waste bin Includes hardware for securing larger drums to the dolly Includes five 2 non marking caster wheels 3 non lockin...

Page 32: ...tter quality products SAFETY WARNING PLEASE READ Before Purchasing or Installing a dust collection system the buyer is cautioned to do so in accordance with prescribed Federal State Local OSHA NFPA an...

Page 33: ...31 oneida air com Notes...

Page 34: ...of where you purchased your system if you have any questions or issues with missing damaged parts please call Oneida Air Systems first to let us help resolve your problem We fully stand behind the qu...

Reviews: