Oneida Air Systems, Inc.
26
Troubleshooting
If you continue to experience difficulty with your dust collector, call Oneida Air Systems’ Customer Service
Department at 1-866-387-8822 or email [email protected].
PROBLEM
CAUSE
SOLUTION
Motor Overheating/System
Tripping
(The motor’s overload
will trip if the motor is
overheating)
Motor not properly wired
1. Check wire connections.
2. Check breaker box to make sure power supply is correct for motor.
Poor dust pick-up at Tools
System and ductwork
connections
1. Check length of duct runs, duct diameters, and hood design compared to ductwork
design guidance.
2. Make sure all connections to the system are sealed. Large air losses will occur even
through small cracks in the flex hose or ductwork. Use silicone, duct tape or duct
mastic compound as a sealant.
3. Make sure everything is connected.
4. Check for air leaks between collector and dust drum.
5. Be sure that your filter is clean.
One of the three motors may
have reached its end of life
1. Replacements can be found in the Recommended Accessories section.
2. Review the Maintenance section on how to replace the motor.
Filter Clogging
Large chips clogging the filter
1. Check for a leak in the dust bin or lid.
2. Make sure dust bin has not over filled. Dust bin should be emptied before the dust
reaches top of container.
Fine dust clogging the filter
1. Heavy sanding with a drum sander or fine grit paper will cause the pleated filter
media to bind sooner than with larger size dust. Clean filter more often with
compressed air.
System Lost Suction
One of the three motors may
have reached its end of life
1. Replacements can be found in the Recommended Accessories section.
2. Review the Maintenance section on how to replace the motor.
Summary of Contents for Supercell XSK000030
Page 2: ......
Page 33: ...31 oneida air com Notes...