MOTOR
MAGNETIC
STARTER
1 2 3 4 5
LEVER
NUT
5 4 3 2 1
LEVER
NUT
MOTOR
MOTOR
Wire 1
Wire 2
Ground Wire
Magnetic Starter Wire
Dust Sentry Wire
System Power Wire
oneida-air.com
25
Maintenance (Continued)
9. Place the new motors onto the assembly then lower the
motor hold down plate back into position. Ensure that the
motor hold down plate is in the correct orientation as noted
by the UP label. The motor wires should rest above the
plate and each unit features tabs that should align with the
notches on the hold down plate.
10. Re-wire the motors.
a. There is no polarity.
b. DO NOT tamper with the grounding wire.
c. Keep wiring consistent, the same wire from each
motor should be inserted into the same lever nut.
d. Open lever and insert one wire into each hole in
lever nut. Close lever and make sure each wire is
secure.
11. Re-secure the motor hold down plate using the five 5/16-18
Nylock Nuts.
Note: DO NOT OVERTIGHTEN. Install the provided spacers
over the threaded studs to determine the correct depth to
drive the nuts.
12. Replace the plenum plate.
13. Re-install the molded cowling and the Nylock nut that
secures it. Clean then install the filter foam on top of the
molded cowling.
Summary of Contents for Supercell XSK000030
Page 2: ......
Page 33: ...31 oneida air com Notes...