NCP1219PRINTGEVB
http://onsemi.com
28
Figure 44. Test Setup
Table 3. NORMAL OPERATING CONDITIONS
Input Voltage
(Vac)
Line Frequency
(Hz)
Load Current (A)
115
60
0.01
0.3125 (25%)
0.675 (50%)
0.9375 (75%)
1.25 (100%)
2.00
230
50
0.01
0.3125 (25%)
0.675 (50%)
0.9375 (75%)
1.25 (100%)
2.00
Table 4. DESIRED RESULTS
Input Voltage
I
OUT
For 115 Vac /
60 Hz input
70 mA
7 V < V
OUT(standby)
<
8 V
70 mA
P
IN
< 1 W
I
OUT
specified
in Table 3
V
OUT
= 24
±
0.2 V
25%, 50%,
75%, 100%
h
avg
> 83.5%
For 230 Vac /
50 Hz input
70 mA
7 V < V
OUT(standby)
<
8 V
70 mA
P
IN
< 1 W
I
OUT
specified
in Table 3
V
OUT
= 24
±
0.2 V
25%, 50%,
75%, 100%
h
avg
> 83.5%
Table 5. STANDBY MODE MEASURED RESULTS
Input Voltage
Parameter
Result
115 Vac / 60 Hz
Input
V
OUT(standby)
P
IN(standby)
230 Vac / 50 Hz
Input
V
OUT(standby)
P
IN(standby)