Positioning
62
ZX2 User’s Manual
INTRODUCTION
MAIN
APPLICATIONS
& SETTING
METHODS
SPECIFI-
CATIONS
INDEX
SETTING
TRANSITION
CHARTS
DETAILED
SETTINGS
FLOW OF
OPERATION
CONTENTS
PREPARATION
FOR
MEASUREMENT
BASIC
SETUP
TROUBLE-
SHOOTING
Height
Double
Sheet
Detection
Positioning
Eccentricity
and Surface
Deflection
Steps
and
Warpage
Thickness
3
Response time setting
4
Smart tuning
*
To tune multiple workpieces or to tune workpieces having a different surface
condition:
page 74
Press the button to set the
display to
to set display of
the detail menu.
Press the
button to apply
the setting.
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Press the button to display
.
Select the
desired value.
Press the button to select the
response time.
Select the response time to
match the size and moving
speed of the sensing object.
to
60 µs, 120 µs, 240 µs, 500 µs,
1 ms, 2 ms, 4 ms, 8 ms, 12 ms,
20 ms, 36 ms, 66 ms, 128 ms,
250 ms, 500 ms
Press the
button to apply
the setting.
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
—
—
Check that the reference
workpiece is set in place.
Press the
button for one
second. When
/
is displayed, release
your finger from the button to
start execution of smart tuning.
If "
" flashes on the
sub-display for three
seconds, it indicates that
tuning was not possible.
Change the response time
setting to a larger value, and
try again.
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Press to display.
Required
Select the response time to match the size
and moving speed of the sensing object.
Press to display
.
Default value: 500 ms
Press to select
Required
Smart tuning sets optimum sensing conditions
according to the operating conditions (response
time and color/state of workpiece)
Hold down for
1 second
Flashing
Pressing down