Thickness
56
ZX2 User’s Manual
INTRODUCTION
MAIN
APPLICATIONS
& SETTING
METHODS
SPECIFI-
CATIONS
INDEX
SETTING
TRANSITION
CHARTS
DETAILED
SETTINGS
FLOW OF
OPERATION
CONTENTS
PREPARATION
FOR
MEASUREMENT
BASIC
SETUP
TROUBLE-
SHOOTING
Height
Double
Sheet
Detection
Positioning
Eccentricity
and Surface
Deflection
Steps
and
Warpage
Thickness
5
2-sensor operation (thickness)
6
Hold
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
—
—
Set the reference sensing object
of which thickness is known in
place.
Press the button on the CH2
Amplifier Unit to display
.
Press the button to display
.
Press the
button to apply
the thickness setting.
Press the button to enable
setting of the thickness numeric
value.
Set any value.
Press the
button to move
the digit, press the button to
change the numeric value, and
set the thickness numeric value.
* If the button is pressed
when the cursor is at the
right-most digit or the
button is pressed when the
cursor is at the left-most digit,
the setting will be canceled.
Press the
button to apply
the setting.
* The 2-sensor operation
reference value is determined
based on the measured values
of CH1 and 2 by the timing that
setting of the thickness numeric
values is executed.
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Press the button on the CH2
Amplifier Unit to display
.
Required
Make this initial setting to measure thickness
by the CH2 Amplifier Unit when using two
Sensor Head to measure thickness.
CH1
CH2
Calculating Unit
(Calculation result is output.)
Press to display
.
Press to select
Press to set.
[Change numeric value]
[Move digit]
Optional
Set this item on the CH2 Amplifier Unit to hold measured values during
the measurement period according to preset hold conditions.
Press to display
.
Default value: OFF