Display Operations
Section 4-1
109
4-1-2
Indicators
Laser ON Indicator: LD ON (Green)
The laser ON indicator is lit when the Sensor Head is emitting a laser
beam (Laser Diode: LD).
Judgement Indicators: HIGH (Orange), PASS (Green), and LOW (Yellow)
The judgement indicators light according to the conditions shown below.
Each judgement output operates in the same way.
Main Display: 5-digit Digital Display (Red)
The measured value (mm) is displayed in RUN Mode.
The hold value (mm) is displayed in the Hold Mode.
Characters are displayed upside down in Display Reverse Mode.
Sub-display: 5-digit Digital Display (Yellow)
The resolution or incident level is displayed in RUN Mode.
The threshold values are displayed in T Mode.
Characters are displayed upside down in Display Reverse Mode.
Enable Indicator: ENABLE (Green)
The Enable Indicator is turned ON/OFF according to the following condi-
tions.
Zero Reset Indicator: ZERO (Green)
The zero reset indicator lights when the zero reset function is enabled.
HIGH indicator
Measured value > HIGH threshold
PASS indicator
LOW threshold
≤
Measured value
≤
HIGH threshold
LOW indicator
Measured value < LOW threshold
ON
During normal emission: Measurement enabled.
OFF
For non-measurement: Inadequate or excessive incident
level, outside the measurement range, or the Sensor Head is
not connected at power-ON
Summary of Contents for ZX Series
Page 1: ...Cat No Z157 E1 01B OPERATION MANUAL ZX Series Smart Sensors ...
Page 2: ......
Page 3: ...Smart Sensors ZX Series Operation Manual Cat No Z157 E1 01B OMRON Corporation ...
Page 48: ...OutlineofFunctions Section 2 5 28 Memo ...
Page 160: ...FUN Function Mode Section 4 5 140 Memo ...
Page 166: ...Setting Problems Section 5 2 146 Memo ...
Page 186: ...Dimensions Section 6 2 166 Memo ...
Page 187: ......
Page 188: ...Z157 E1 01B ...