Through-beam Sensor Heads: FUN Mode Functions
Section 3-8
81
l
Inverting Display Values
When inverting the display values is set, the display values will be in an
inverse relationship to the reference values.
Normally, the more the measured value between Sensor and sensing
object increases, the larger the display value becomes. However, if the dis-
play values are inverted, the more the measured value increases, the
smaller the display value will become.
Inverting display values is not possible when two-point scaling is used.
When scaling cannot be set correctly, refer to
5-2-1
Unable to Set Scaling
.
When any of the following changes is performed, the scaling func-
tion is automatically cleared and must be performed again.
• Turning ON or OFF Intensity Mode.
• Enabling or disabling two-sensor operation A + B.
• Enabling or disabling two-sensor operation A
−
B.
POINT