Through-beam Sensor Heads: FUN Mode Functions
Section 3-8
82
n
Offsetting Display Values: One-point Scaling A
Use one-point scaling to offset the display values. Input the width to be dis-
played for the current measurement point.
When you input only one point for scaling, only the offset is changed with-
out changing the range of display values. In this example, the display val-
ues are not inverted.
Example: One-point Scaling A
Sensor Head Emitter
X
Sensor Head Receiver
When displaying X= 2.5 as
5 mm is required
Sensing object
1.5
4.0
1.5
2.0
4.5
2.0
2.5
5.0
2.5
3.0
5.5
3.0
Measured value = Display value
Measured value
Display value
: Scaling value input
2.5 mm is displayed as 5.0 mm.
Display value
(mm)
5.0
2.5
Despite the offset value,
the range remains unchanged.
2.5
Actual incident beam width (mm)