1. Do not install the product in locations subjected to the following conditions:
・
Reflection of intense light (such as other laser beams or electric arc-welding
machines)
・
Presence of dust, oil droplets or spray on the filter on the front of the Sensor
Head
・
Presence of corrosive or flammable gases
・
Direct vibration or shock
2. Pre-installation Checks
・
The product cannot accurately measure the following types of objects:
(transparent objects, objects having an extremely low reflection factor, objects
smaller than the spot diameter, objects with a large curvature, excessively
inclined objects, etc.)
3. Wiring
・
Avoid wiring the cable between the Sensor Head and Sensor Controller
including this product near high voltage lines and power lines.
Wiring them together or placing them in the same duct may cause induction,
resulting in malfunction or damage.
・
Before connecting/disconnecting the Sensor Head, make sure that the Smart
Sensor is turned OFF. The Smart Sensor may break down if the Sensor Head is
connected or disconnected while the power is ON.
4. Cleaning
・
Do not use paint thinner, benzene, acetone or kerosene to clean the Sensor
Head. Doing so will melt the surface of the Sensor Head.
・
To remove dust particles, use a blower brush.
・
To remove stubborn dirt, wipe gently with a soft cloth moistened with a small
amount of alcohol.
5. Compatibility
・
The Sensor Head is compatible with the Sensor Controller, and can be used if
purchased separately.
Please observe the following precautions for safe use of the product:
1. Do not use the product in environments where it can be exposed to
inflammable/explosive gas.
2. Do not disassemble, repair or modify this product.
3. Be sure to make sure that locking mechanisms are locked before use.
4. Dispose of this product as industrial waste.
■
Dimensions
PRECAUTIONS ON SAFETY
© OMRON Corporation
2005
All Rights Reserved.
Model
ZS-HLDS5/HLDS5T
Sensor Head for Smart Sensor ZS-HLDC
□□
PRECAUTIONS FOR SAFE USE
PRECAUTIONS FOR CORRECT USE
■
Handling Precautions
・
The ZS-HLDS5/HLDS5T emits a visible laser beam. Do not stare directly into the laser.
Make sure that the laser beam path is terminated.
A non-reflective matte painted surface is ideal at the end of the laser beam path.
If specular objects are present in the laser beam path, make sure that they are prevented
from reflecting the laser beam. When used without an enclosure, make sure the laser
path from eye level is avoided.
■
Export and Trade Control Laws
The ZS-HLDS5 is classed as a commodity (or technology) requiring
acquisition of export permission in accordance with foreign exchange
and overseas trade control laws. When the ZS-HLDS5 is to be taken
outside of Japan, adopt the required procedures such as application for
export permission by the Japanese government.
* Contact your OMRON representative.
■
Various safety standards regarding laser devices are stipulated depending on the
country of use.
The following describes the method of use according to where the product is exported.
(1) Using in U.S.
When using devices in which this product is installed in U.S., the devices are
subjected to the U.S. FDA (Food and Drug Administration) laser regulations.
LASER SAFETY
●
Meanings of Signal Words
●
Alert Statements in this Sheet
●
Meaning of Alert Symbols
WARNING
Indicates a potentially hazardous situation which, if
not avoided, will result in minor or moderate injury,
or may result in serious injury or death. Additionally,
there may be significant property damage.
WARNING
Never look into the laser beam.
Doing so continuously will result in visual impairment.
Do not disassemble the product.
Doing so may cause the laser beam to leak,
resulting in the danger of visual impairment.
Indicates the possibility of laser radiation.
Indicates prohibition when there is a risk of minor
injury from electrical shock or other source if the
product is disassembled.
ZS-HLDS5/HLDS5T
*1 Defined as 1/e
2
(13.5 %) of the center optical intensity in the measurement center distance (effective value). The beam diameter is sometimes influenced by the ambient conditions of the workpiece such as leaked light from the main beam.
*2 This is the error on the measured value with respect to an ideal straight line. In the diffuse reflection mode, the standard workpiece is white aluminumceramic, and is glass in the regular reflection mode. Linearity may change according to the
workpiece.
*3 This is the "peak-to-peak" displacement conversion value of the displacement output in the measuring center distance when the number of samples to average is set to 512, and the measuring mode is set to high-resolution mode. In diffuse reflection
mode, the standard workpiece is white aluminum ceramics, and glass in the regular reflection mode.
*4 This is the typical value obtained in the measuring center distance when the sensor and workpiece are fixed by an aluminum tool.
*5 This value is obtained when the measuring mode is set to the high speed mode.
(2) Using in a country other than U.S.
・
For countries other than Japan and U.S.,
warning labels must be replaced by English
ones (supplied with the product).
・
EN60825 is provided for products used in
Europe, and the content of this standard differs.
The ZS-HLDS5/HLDS5T is categorized as a
Class 2 device as stipulated in EN60825-1
(IEC60825-1).
(unit: mm)
■
Specifications
Optical system
Diffuse reflection
Regular reflection
Diffuse reflection
Regular reflection
Measuring center distance
50mm
44mm
50mm
44mm
Measuring range
±
5mm
±
4mm
±
5mm
±
4mm
Light source
Visible semiconductor laser (wavelength 650 nm, 1mW max. , Class 2)
Beam diameter (*1)
30
×
1000
μ
m
Linearity (*2)
±
0.1%F.S.
Resolution (*3)
0.1
μ
m 0.25
μ
m
Temperature characteristic (*4)
±
0.01%F.S./
℃
Sampling cycle (*5)
110
μ
s
NEAR indicator
Lit near measuring center distance, and nearer than measuring center distance inside the measuring range
Indicators
Blinks when the measurement target is outside of the measuring range or when the received light amount is insufficient
FAR indicator
Lit near measuring center distance, and further than measuring center distance inside the measuring range
Blinks when the measurement target is outside of the measuring range or when the received light amount is insufficient
Operating ambient illumination
Illumination on received light surface 3000 lx or less (incandescent light)
Ambient temperature
Operating: 0 to +50
℃
, Storage:
-
15 to
+
60
℃
(with no icing or condensation)
Ambient humidity
Operating and storage: 35% to 85% RH (with no condensation)
Degree of protection
Cable length 0.5 m: IP66, cable length 2 m: IP67
Vibration resistance (destructive)
10 to 150 Hz, 0.35-mm half amplitude 80 min each in X, Y, and Z directions
Shock resistance (destructive)
150m/s
2
3times each in six directions (up/down, left/right, toward/backward)
Materials
Case: aluminum die-cast, front cover: glass
Cable length
0.5 m, 2 m
Weight
Approx. 600 g
Accessories
Laser label (1 each for JIS/EN
、
3 for FDA), Ferrite core (4 pcs), Insure Lock (2 pcs), Instruction Sheet
Item
Model ZS-HLDS5
ZS-HLDS5T
Replace the warning label with the corresponding English
label (supplied with the sensor).
CAUTION
PEAK POWER
PULSE DURATION
WAVE LENGTH
1000
10000
650
μw
μs
・
Place to affix the label
AVOID
EXPOSURE
Laser radiation
is emitted from
this aperture
This laser product complies with
21 CFR 1040.10 and 1040.11.
Shiokoji Horikawa, Shimogyo-ku,
Kyoto 600-8530 JAPAN
OMRON Corporation
AYABE Factory, OMRON Corp.
Place of manufacture:
Manufactured in
Class 2 Caution Label
Certification Label
Laser Emission
Opening Label
INSTRUCTION SHEET
Thank you for selecting OMRON product. This sheet pri-
marily describes precautions required in installing and
operating the product.
Before operating the product, read the sheet thoroughly to
acquire sufficient knowledge of the product. For your con-
venience, keep the sheet at your disposal.
Manufacturer:
Omron Corporation,
Shiokoji Horikawa, Shimogyo-ku,
Kyoto 600-8530 JAPAN
TRACEABILITY INFORMATION:
Importer in EU :
Omron Europe B.V.
Wegalaan 67-69
2132 JD Hoofddorp,
The Netherlands
The following notice applies only to products that carry the CE mark:
Notice:
This is a class A product. In residential areas it may cause radio
interference, in which case the user may be required to take adequate
measures to reduce interference.
■
Attaching the ferrite core
Attach three ferrite cores (provided with the Sensor Head) to the Sensor Head
side of the Sensor Head cable, and attach one ferrite core to the connector side
of the Sensor Head cable.
If the ferrite core comes loose from the cable, fasten the ferrite core in place with the
Insure Lock (supplied).
Ferrite core
Insure Lock
Ferrite core
Suitability for Use
s
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer’s application or use of the Product. At Buyer’s request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
Oct, 2014
D
OMRON Corporation
Industrial Automation Company
Contact: www.ia.omron.com
Tokyo, JAPAN
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
Regional Headquarters
R154
3-M4
9.5±0.1
70±0.1
69±0.1
18
36
46
92.1
8
(15)
9.5
Dia. 21
82
(5)
30°
4
9.5
70
72
80
R2
5-R1
50
16.4
25
25
69
100
16.9
45.1
R2
3-Dia. 4.5 MOUNTING HOLES
22.7
Dia. 13
MOUTING SCREW HOLES
RECEIVING PART
RECEIVING AXIS
LIGHTENING PART
CENTER
LIGHTENING AXIS
STANDARD SURFACE
STANDARD SURFACE
VINYL INSULATED ROUND CORD
Dia. 6.8 STANDARD LENGTH 2M
AXIS
CONNECTOR
OPERATING INDICATOR