![background image](http://html.mh-extra.com/html/omron/zfx-c/zfx-c_command-reference-manual_1633352033.webp)
About Communication Commands
ZFX-C Serial Communication Command Reference
31
Backing up Image Data < IMGSAVE command >
Backing up image data from the Controller to an external device
This command backs up image data from the Controller by XMODEM protocol.
< Command format >
< File transfer >
The image data is transferred by XMODEM (-CRC or SUM) after READY is received. XMODEM (-1K) is not
supported.
< Response format >
< Explanation of parameters >
Save memory No.
Specifies the No. of the save memory for backing up the image data to. (0 to 99)
When "-1" is specified for the Save memory No., the latest image data of camera 0 is
specified.
When "-2" is specified for the Save memory No., the latest image data of camera 1 is
specified.
I M G S
CR
I S
CR
A V
E
0
0
or
Save
memory No.
(max. 2 digits)
Save
memory No.
(max. 2 digits)
O K
CR
E R
CR
R
E A
D
CR
Y
When processing ends successfully
When processing fails