![background image](http://html.mh-extra.com/html/omron/zfx-c/zfx-c_command-reference-manual_1633352054.webp)
About Communication Commands
52
ZFX-C Serial Communication Command Reference
Count
Angle
Data No.
Parameter
Output Range
51
Search mode
0: Normal, 1: Fine
52
Color mode
0: Color filter, 1: Color Pickup
53
Target color
0: Light, 1: Dark
54
Edge level
1 to 99
55
Noise level
0 to 255
56
Noise width
0 to 255
57
Calibration
0: OFF, 1: ON
71
Number of edges upper limit value
0 to 255
72
Number of edges lower limit value
0 to 255
73
Average pitch upper limit value
0.000 to 9999.999
74
Average pitch lower limit value
0.000 to 9999.999
75
Average width upper limit value
0.000 to 9999.999
76
Average width lower limit value
0.000 to 9999.999
Data No.
Parameter
Output Range
51
Color mode
0: Color filter, 1: Color Pickup
52
Measurement mode1
0:Average, 1: Peak, 2: Bottom
53
Split size1
1 to 99
54
Color1
0: Light
→
Dark, 1: Dark
→
Light
55
Edge level1
1 to 99
56
Noise level1
0 to 255
57
Noise width1
0 to 255
58
Measurement mode2
0:Average, 1: Peak, 2: Bottom
59
Split size2
1 to 99
60
Color2
0: Light
→
Dark, 1: Dark
→
Light
61
Edge level2
1 to 99
62
Noise level2
0 to 255
63
Noise width2
0 to 255
64
Calibration
0: OFF, 1: ON
65
Coordinates mode
0: Normal, 1: Pos. correction
71
Angle upper limit value
-180.00 to 180.00
72
Angle lower limit value
-180.00 to 180.00
73
Region1 X upper limit value
-9999.999 to 9999.999
74
Region1 X lower limit value
-9999.999 to 9999.999
75
Region1 Y upper limit value
-9999.999 to 9999.999
76
Region1 Y lower limit value
-9999.999 to 9999.999
77
Region2 X upper limit value
-9999.999 to 9999.999
78
Region2 X lower limit value
-9999.999 to 9999.999
79
Region2 Y upper limit value
-9999.999 to 9999.999
80
Region2 Y lower limit value
-9999.999 to 9999.999