About Communication Commands
44
ZFX-C Serial Communication Command Reference
Brightness and color inspection parameters
Brightness
Hue
Data No.
Parameter
Output Range
0
Judgment result
0: OK
-1: NG
-2: not measured
1
Density average
0 to 255.0
2
Density deviation
0 to 127.0
3
Reference density average
0 to 255.0
4
Reference density deviation
0 to 127.0
5
Density average difference
0 to 255.0
6
Density deviation difference
0 to 127.0
Data No.
Parameter
Output Range
0
Judgment result
0: OK
-1: NG
-2: not measured
1
Hue
0 to 360.0
2
Saturation
0 to 100.0
3
Value
0 to 100.0
4
Hue deviation
0 to 180.0
5
Saturation deviation
0 to 50.0
6
Value deviation
0 to 50.0
7
Reference hue
0 to 360.0
8
Reference saturation
0 to 100.0
9
Reference value
0 to 100.0
10
Hue difference
-360.0 to 360.0
11
Saturation difference
-100.0 to 100.0
12
Value difference
-100.0 to 100.0
13
Reference hue deviation
0 to 180.0
14
Reference saturation deviation
0 to 50.0
15
Reference value deviation
0 to 50.0
16
Hue deviation difference
-180.0 to 180.0
17
Saturation deviation difference
-50.0 to 50.0
18
Value deviation difference
-50.0 to 50.0
19
Maximum hue
0 to 360.0
20
Minimum hue
0 to 360.0
21
Maximum saturation
0 to 100.0
22
Minimum saturation
0 to 100.0