5
Nomenclature
Range indicator (green/red)
Stability indicator (green/red)
Optical axis marker
Transmitter
Receiver
Operation
Connections/Output Circuits
Power supply
(Brown) 12 to 24 VDC
. . . .
GND
(Blue) 0 V
. . . . . . . . . . . .
DARK output
(Orange) 50 mA max. at 30 VDC
. . . .
Analog output
(Black) 40 to 20 mA
. . . .
GND
(Shield)*
. . . . . . . . . . . .
Load power supply
(30 VDC max.)
12 to 24 VDC
4 to 20 mA
0 V
(Red)
(White)
(Shield)
(Black)
Linear
differentiator, etc.
Signal processor
(Orange)
Note:
1. *The two ground terminals (black and shield) are inter-
nally connected. However, the black ground must be
used with the red terminal for the power supply and the
shield ground must be used with the white terminal for
the analog output.