WX2B
WX2B
7
29.5
(1.16)
15.5
45
(1.77)
46
(1.81)
44.3
(1.74)
3.5
3.5
180 (7.09)
7.62
20.5
2.8
7
6.2
Two, 3.5
dia. holes
XW2B-40J6-2B
Note: The terminal block has a terminal pitch of 7.62 mm.
NC Module side
X--axis Servo side
Triangle mark
Terminal block (40 P) with rotary cover
Y--axis Servo side
M3
2.8
63.6 (2.50)
54.7 (2.15)
Connection to Multi Axis Position Control Modules
C200H-NC211-U/C200HW-NC213-U/C200HW-NC413-U
Note: 1. The XB contact is used to turn the electromagnetic brake on and off.
2. Use mode 2 for origin search.
3. When only a single axis is used, short--circuit the unused axis’ CW limit and CCW limit to the common terminal.
4. The open terminal must be left unconnected.
5. 0 V and common terminals are connected internally.
6. The suitable crimp terminal is R1.25-3 (round or fork type).
Com--
mon
X/Y--ax-
is emer--
gency
stop
X--ax-
is CW
limit
Com--
mon
X--axis
remote
interrupt
X--ax-
is
CCW
limit
X--ax-
is ori-
gin
prox--
imity
X--ax-
is
RUN
X--axis
MING
X--axis
ALM
X--ax-
is
BKIR
Y--
axis
CW
limit
Y--
axis
CCW
limit
Y--axis
origin
prox--
imity
Y--axis
RUN
Y--axis
MING
Y--axis
ALM
Y--
axis
BKIR
X--axis
RESET
X--
axis
ALM
COM
Y--axis
remote
interrupt
Y--axis
RESET
Y--axis
ALM
COM
Com--
mon
Com--
mon
Com
--mon
Com--
mon
Com--
mon
Com--
mon
Com--
mon
24
VDC
24 VDC
24
VDC
(see
note 1)
(see
note 1)
Connection to Terminal Block
The terminal signal name varies with the
servo driver. Refer to the Operation
Manual of the servo driver in use.
Identify the servo driver in use by writing
the name on the terminal nameplates
provided. Affix the nameplate to the
terminal cover.
7.5