background image

INSTRUCTION SHEET

Thank you for selecting OMRON product. This sheet pri-

marily describes precautions required in installing and

operating the product.

Before operating the product, read the sheet thoroughly to

acquire sufficient knowledge of the product. For your con-

venience, keep the sheet at your disposal.

1.To ensure safety, be absolutely sure to follow the instructions 

below:

(1) NEVER use the product in an environment where combustible 

or explosive gas is present.

(2) If abnormal odor or noise occurs, if the outside surface is 

excessively hot, or if the product emits fume, immediately 
stop the operation and power OFF the product.

(3) IF the product is accidentally dropped or damaged, 

immediately power it OFF and contact your nearestOMRON 
representative for technical support.

6.Part 15 of the FCC Rules
  For a Class A digital device or peripheral, the instructions furnished 

the user shall include the following or simillar statement, placed in 
a prominent location in the text of the manual:

NOTE : This equipment has been tested and found to comply with 

the limits for a Class A digital device, pursuant to part 15 of the 
FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference when the equipment is 
operated in a commercial environment. This equipment genarates, 
user, and can radiate radio frequency enegy and, if not installed and 
used in accordance with the instruction manual, may cause harmful 
interference to radio communications. Operation of this equipment 
in a residential area is likely to cause harmful interference in which 
case the user will be required to correct the interference at his own 
expense.

© OMRON Corporation  

2003

 All Rights Reserved.

PRECAUTIONS ON SAFETY

Dimensions

* Be sure to limit the tightening torque for the M4 screws
   to 1.2 N-m or less.

(Unit: mm)

-- Document conventions -- symbols (signal words) and their 
meanings
Throughout this document, the signal and associated symbols 
(icons) are used to allow the operator to use this unit. The 
statements marked with signal words describe important 
safety-related instructions that must be strictly observed. The 
symbols and meanings are as given below:

Indicates a potentially hazardous situation 
which, if not avoided, may result in minor 
or moderate injury or in property damage.

CAUTION

CAUTION

Never use AC adapter other than V600-A20.
If you use other AC adapter, it may cause 
malfunction, injury and fire.

PRECAUTIONS FOR SAFE USE

PRECAUTIONS FOR CORRECT USE

1.About environments of installation
   Do not install or leave the product to a location such as:
(1) Location subjected to direct sunlight
(2) Location where corrosive gas, dust, metal dust, salty air is 

present

(3) Location where the operating temperature can exceed or drop 

below a range defined in the specification

(4) Location where temperature change is great, and can lead to 

dew condensation

(5) Location with higher humidity, and can lead to dew 

condensation

(6) Location where vibration or impact whose magnitude greater 

than specified can be directly transmitted to the product proper

(7) Location where splash pf water, oil or chemical product is 

present

2.About installation
(1) This product operators on the 125kHz frequency band to 

communicate with an ID tag. Certain transceivers, motors, 
monitors, and power supplies (power ICs) can emit a radio 
frequency wave (noise) that can adversely affect 
communications with an ID tag. When planning to use the 
product near such a source, study the possible result in 
advance.

(2) To minimize the possible noise interference, earth-ground 

(class D earth work) a metal object that will be located around 
the product.

3.About wiring work
(1) Before starting a wiring work or disconnecting a cable, be sure 

to power OFF the product

(2) Do not run the cable for the product in a conduit common to a 

high voltage line and a power supply line.

(3) To avoid static-induced failure, wear a wrist band or equivalent 

means to release a static charge before touching a terminal or a 
signal line within a connector.

4.About thread glue
(1) A thread glue can deteriorate and lead to crack on a resin part. 

Thus, do not apply a thread glue to the threading on a resin 
part or to resin-made washers.

5.About cleaning
(1) NEVER use an organic solvent such as thinner or benzene, as 

it will attack resin components or case coating.

Interface specifications

11

Characteristic

Specification 

Connector
specification

9-pin D-SUB connector socket

Communication
standard

RS-233C

Synchronization

Asynchronous mode, start-stop synchronization

Communication
control standard

OMRON original 1:1 protocol

Band rate (fixed)

9,600 bps

Character format
(fixed)

Start bit Data bit Parity bit Stop bit

Total

Even

Error control

Even parity

RS-232C connector pin arrangement

No.

1

2
3

4

5

6

7

8

9

Signal name

Send data

Receive data

Request send

Clear to send

Signal ground

Symbol

SD

RD

RS

CS

SG

Comment

Normally ON

Direction

Input

Output

(1) Connector pin number is writen in D-SUB connector.

Cable

PVC (oil-resistant)

Filler resin

Epoxy resin

Case material

ABS resin

General specifications

Characteristic

Supply voltage

Protection rating

Insulation
resistance

Dielectric

Shock resistance

Vibration
resistance

Weight

Ambient
humidity

Ambient
temperature

Current consumption

Specification 

5VDC, 

5%, 

5% (supplied from V600-A20)

200 mA max

 IP67 (IEC 60529), IP67g (JEM 1030)
(The connector is not resistant to water or oil.)

300m/s

2

, 3 times each in 6 directions

About 210g (Cable length is 2m)

1000V AC (50/60Hz, for 1 min.) 
leak current consumption 1mA max.
(between all connector terminals and case)

50MΩ

 min. (500V DC for appliance)

(between all connector terminals and case)

Operating: 25 to 85%RH, Storage: 25 to 95%RH
(No freezing, No dew condensation)

Operating: 

10

 to 

55

℃,

 Storage: 

25

 to 

65

(No freezing, No dew condensation)

10 to 150Hz, 1.5mm double amplitude, 
with 4 sweeps of 8min each in 3 directions

Applied standards R&TTE / FCC Part15 Subpart C

Carrier detection

CD

Internally connected to DR

Data set ready

DR

Output

Internally connected

to each other

OMRON Corporation

Suitability for Use

EUROPE
OMRON EUROPE B.V. Sensor Business Unit
Carl-Benz Str.4, D-71154 Nufringen Germany
Phone:49-7032-811-0  Fax: 49-7032-811-199

NORTH AMERICA
OMRON ELECTRONICS  LLC
One Commerce Drive Schaumburg,IL 60173-5302 U.S.A
Phone:1-847-843-7900 Telephone Consultation
1-800-55-OMRON    Fax : 1-847-843-7787

ASIA-PACIFIC
OMRON ASIA PACIFIC PTE LTD
83 Clemenceau Avenue,#11-01 UE Square,Singapore 239920
Phone : 65-6-835-3011 /Fax :65-6-835-2711

n

THE PRODUCTS CONTAINED IN THIS SHEET ARE NOT SAFETY RATED.  
THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF 
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY 
COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES.
Please refer to separate catalogs for OMRON's safety rated products.

OMRON shall not be responsible for conformity with any standards, codes, or 
regulations that apply to the combination of the products in the customer's 
application or use of the product. 
 
Take all necessary steps to determine the suitability of the product for the 
systems, machines, and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
 
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING 
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE 
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 
AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND 
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL 
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.

10

5

5

28

±

0.1

28

±

0.1

27

±

0.2

2-M4 OR 4.5dia.

CENTER OF COIL

MOUNTING SCREW HOLES

15

23

11

13

18

5

32

45.5

45 

14dia.

20

6

27

53

40

OPERATION INDICATOR

4-R1

BUSH

2-4.5dia.(MOUNTING HOLES)

2-10dia.

When installed from the reverse side,

insert the attached nuts into the holes "A".

ATTACHED
NUTS FOR M4

A

VINYL INSULATED ROUND CODE 6dia.
STANDARD LENGTH 2M

VINYL INSULATED FLAT CODE (1.8dia.x2)
STANDARD LENGTH 0.19M

CONNECTOR:EIAJ RC5320A JSAP2(RECEPTACLE)

9PIN D-SUB CONNECTOR

Model

V700-HMD11

ID System  Reader/Writer

V700-HMD11-R

*1) In dimensions of V700-HMD11-R, the cord is different from V700-HMD11.
      The cord of V700-HMD11-R is as follow;
      " ROBOT INSTRUMENTAL CABLE 5.7dia. STANDARD LENGTH 2m"