background image

 

JBM INSTRUMENTOS LTDA 

Rua Araguaia, nº 69 

– Boa Vista, Santa Rita do Sapucaí – MG - CEP: 37540-000 

Tel / Fax: +55 (35) 3471-3014 

www.jbminstrumentos.com.br - [email protected] 

 

Surecom Digital VHF/UHF SWR & Power Wattmeter 

SW-102 

120W, 50Ω, 125 - 520MHz

 

Introduction

 

 

VSWR. Forward and reflected power direct digital readout, without 
any calibration; 

 

Maximum measurable power range up to 120W; 

 

Low insertion loss (0.3 decibels or less) structure allows it to be 
permanently connected; 

 

Build in Frequency counter. 

Feature & Specification

 

 

Frequency Range: 125 to 525MHz 

 

Measurable power range: 0.5 - 120W (±0.5%) 
(Measurable power, Radio must be ANALOG) 

 

Maximum power: 120W

 

 

Frequency counter: Yes (TX input must be minimum 0.5W ±0.5%) 

 

VSWR: 1.00~19.9 

 

Insertion Loss: <0.15dB(VHF) , <0.25dB(UHF) 

 

Impedance: 50Ω

 

 

Charger in: 5V (micro USB) 

 

Backlight: AUTO OFF  

 

Battery Build-in: 3.7V  Li-ion Battery 

 

Battery Display: Yes 

 

Auto Power Off: 1-9 mins 

 

Temperature: 0°~60°C 

 

Interface Connectors (In/Out): N Female or UHF Female (SO-239) 

 

Size: 66 x 68 x 37 mm 

 

Weight: 220g (include battery) 

NOTICE:

 

 

This Power & SWR Meter is compatible to Both car radio transceiver and handheld radio, no need another adaptors; 

 

SW-102 is not for Digital mobile radio system (DMR System).  

Power ON/OFF:

 

Press 2 second the [Red button] to power on or power off 
 

MENU Display (Note: Version for up to V3.8)

 

No. 

Mode 

Adj  

Default Setting 

 Content 

Adjustment Forward 

 -99  to  +99 

Fine Tune Level % 

Adjustment Reverse 

 -99  to  +99 

Fine Tune Level % 

Adjustment Time Base 

 -99  to  +99 

Frequency Counter ,OSC Time Base 

LCD DIM (Back Light  Time) 

0-9 

"0" is always on,  1 min  to  9 mins 

POWER OFF 

0-9 

"0" is always on,  1 min  to  9 mins 

 
* Supplier, the product will add functionality without having to give notice 

Set & Save:

 

1.

 

Press MENU [Blue button] 

2.

 

Press F1 [Red button)(Select 1-5 Funtion) 

3.

 

Press [Blue button] ( - ), [Yellow button] (+) 

4.

 

Press the  [Red button ]for 2 seconds 

5.

 

Press the  [Blue button] to SAVE and EXIT 

Reviews: