![Omron V670-H11 User Manual Download Page 48](http://html1.mh-extra.com/html/omron/v670-h11/v670-h11_user-manual_741400048.webp)
3-1 Controller
3-10
3-1-6-1 Wiring Power Supply and Grounding Cable
M3 self-up screws are used for the power supply and ground terminal. For a crimp terminal, use any of terminals below. Tightening
torque should be approximately 0.6 N•m.
♦
Applicable crimp terminal
♦
Recommendable DC power supply (small-sized) (OMRON)
* Rated power consumption of the controller is 24VDC and 0.2 A (7 W). Decide the capacity taking into consideration inrush current
(approximately 5 A).
3-1-6-2 Wiring Reset Signal
Manufacturer
Model
Applicable Wire
Type
Japan Solderless
Terminal
1.25-N3A
AWG24 to
AWG16
Fork
Japan Solderless
Terminal
1.25-Y3A
Model
Output Capacity
Input Voltage
S82K-03024
24 VDC 1.3 A
100/200 VAC
S82J-0224
24 VDC 1.1 A
100 VAC
V6 7 0 - CD1 D
V670-CD1D-V1
ID
Grounding of Class D
+DC24V
0V
(Example of Wiring)
Ferrite core
(attached to the product)
24VDC
Reset Input
O.COM
OUT2
OUT1
RST
/IN
V6 7 0 - CD1 D
V670-CD1D-V1
ID
(For M3)