8-3
Main six causes of troubles in V670 Series are as follows:
• External device failure
• Controller failure
• Antenna failure
• Cable failure
• Tag failure
• Others
♦
Host communication error
♦
Communication error
♦
System error
Error Code
Name
Description
"10"
Parity error
A parity error has occurred in any character of command.
"11"
Framing error
A framing error has occurred in any character of command.
"12"
Overrun error
An overrun error has occurred in any character of command.
"13"
FCS error
FCS of received command is invalid.
"14"
Format error
A command format is incorrect. Character interval has exceeded a preset time.
"15"
Execution status error
Communication designation is Input Trigger (SI/RI/PI) when input setting
is RESET. The "MO" command was executed when no operating condi-
tion is registered.
"18"
Frame length error
A command string more than 300 characters was received.
Error Code
Name
Description
"70"
Communication error
An error has occurred during the communication with a tag and the com-
munication cannot be completed correctly.
"71"
Verification error
Correct data cannot be written into a tag (only when verification is enabled).
"72"
No-tag error
There is no tag in a communication area of antenna when a trigger system
command is executed. In a command which performed communication des-
ignation of "st", there is no tag, which communicated immediately before, in a
communication area of antenna. The antenna is not connected.
"74"
Outstanding tag error
In polling query, a communication process has not yet been completed.
"7A"
Address designation error
Designation of process address is unsuitable and the execution is impossible.
"7D"
Write Protect error
Something was written into a write-protected page.
"7E"
Lock error
Writing into a locked area has been specified.
"7F"
Tag error
Communication has been made to unavailable tag (password is not spec-
ified, etc.).
Error Code
Name
Description
"7C"
Antenna section error
No communication can be executed due to antenna trouble.
"9A"
EEPROM error
An error in writing into/reading from nonvolatile memory in the controller
(the SP/SE command). The "MO" command was executed under invalid
operating condition.
Correct Usage
The details of those error are all stored in the controller and you can read out an error code or error message through the
programming console.
8-3 Errors and Countermeasures
Must be repaired.
Summary of Contents for V670-H11
Page 16: ...1 4...
Page 38: ...2 22...
Page 58: ...3 20...
Page 70: ...4 12...
Page 100: ...6 4...
Page 102: ...7 2 Unit mm 7 2 Outside Dimension...
Page 120: ...7 20...