![Omron V600-CD1D-V2 Operation Manual Download Page 77](http://html1.mh-extra.com/html/omron/v600-cd1d-v2/v600-cd1d-v2_operation-manual_743945077.webp)
Appendix C
Specifications and Ratings
74
Communications Specifications
The communications specifications conform to RS-232C, and a general-purpose factory computer or personal
computer can be connected to the ID Controller. The communications protocol conform to SYSWAY (SYSMAC
host computer system).
Host Computer Communications Specifications
Standard
RS-232C
Transmission path
connection
Point-to-point
Communications method
Two-line, half-duplex
Synchronization method
Start-stop synchronization (stop bit = 1 or 2)*
Transmission rate
2,400/4,800/9,600/19,200 bps*
Transmitted codes
ASCII (7 bits) or JIS*
Communications control
procedure
Point-to-point procedure
Error detection
Vertical parity (even/odd/none)*
Line length
15 m max.
Connector
XM2A-0901 (plug):
1 set is supplied with ID Controller
XM2S-0911 (hood):
As an accessory
Recommended cable
5PX28AWG, 7 dia.
Note *Set by the internal DIP switch.