![Omron V600-CD1D-V2 Operation Manual Download Page 41](http://html1.mh-extra.com/html/omron/v600-cd1d-v2/v600-cd1d-v2_operation-manual_743945041.webp)
4-4
Section
Types of Commands and Responses
36
Expansion write command:
X
W
A/H
1
First address
Write data
∗
CR
Frame is divided if the number of characters is more than 267
Data written to DC
Header
ASCII/HEX code specification
R/W Head No. specification
(fixed to 1)
First address specification
(0002-FFFF)
ASCII
1-2048 characters
(1-2048 bytes)
HEX
2-4096 (4K) characters (even)
(1-2048 bytes)
Note To divide a frame into several frames, make sure that one frame is of 266 charac-
ters or less.
Frame 1
Frame 2
Frame
(n–1)
Frame n
:
:
1 frame = 266 characters max.
Header
A/H
1
First address
Write data 1
CR
CR
Write data (n–1)
Write data 2
Write data n
CR
∗
CR
4-4
Types of Commands and Responses
4-4-1 Read (RD)
Reads data from the Data Carrier. If the Data Carrier is missing, an error re-
sponse (end code: 72 = Data Carrier missing) is returned.
Command Format
R
D
A/H
1
X
X
X
X
∗
Header
ASCII/HEX code specification
A: ASCII code, JIS 8 code
H: HEX code
R/W Head No. specification
(fixed to 1)
First address No.
specification range
0000-07FF (2KB type)
0000-1FFF (8KB type)
Specify the number of bytes to be read in
HEX code. The number of bytes that can
be read at a time is as follows:
– ASCII: 256 bytes (256 characters)
– HEX: 128 bytes (256 characters)
Read
∗
No. of
bytes
read