![Omron V600-CD1D-V2 Operation Manual Download Page 26](http://html1.mh-extra.com/html/omron/v600-cd1d-v2/v600-cd1d-v2_operation-manual_743945026.webp)
3-6
Section
RS-232C Interface Connection
21
Assembly of Connector
1, 2, 3...
1. Process the ends of the cables.
12
40
35
5
Core
Shield mesh
Shield tape
Cable bushing
10
±
1
•
Run the cable bushing through the cable in advance.
•
Loosen the shield mesh and return it on the cable bushing. At this time,
keep the returning length to about 10 mm.
•
Wind the shield tape onto the shield mesh.
2. Solder the cores of the cables to the pins.
Plug Crossover line
Cable bushing
Aluminum tape
Pin no.
Abbr.
Signal name
1*
GR
Frame ground
9
SG
Signal ground
2
SD
Send data
3
RD
Receive data
4**
RS
Request to send
5**
CS
Capable to send
*GR is grounded to the connector hood and is therefore connected to the GR of
the ID Controller through the connector hood. It is therefore unnecessary to con-
nect GR to pin 1.
**Short-circuit pins 4 (RS) and 5 (CS) with a crossover line.
3. Set the plug to the housing A2 of the hood and clamp the aluminum tape.
Lock screw (2-M2.6)
Housing A2
Cable clamp
Housing B2
4. Set the two connector tightening screws and attach housing B2 to A2 to
complete the connector.