Connecting Your V550-A20 To An External Device
You must supply power to the V550-A20 through the 15 pin connec-
tor at the rear of the unit. You can supply power using one of the
following two methods: using an Omron local power supply or
wiring power directly into the V550-A20 using one of your own
methods.
The V550-A20 must meet the following three requirements regardless
of the method that you use to supply power:
• +5VDC must be supplied
(range b4.85VDC and +5.25VDC @ 500 mA typical, 600 mA max.,
maximum ripple 100mV)
• Ground must be supplied
• Metal shell of connector must be grounded
Make sure the metal shell of the connector is grounded. This pro-
vides chassis ground to the unit case, and is necessary for proper
operation.
Using Omron's Power Supply For Power
You can use the Omron S82S-0305 power supply to supply power to
the V550-A20 15 pin "D" connector. Note that a UL class 2 power
supply should be used for UL approval. This power supply is shown
below:
If you use this power supply, you need to connect cable leads to the
V550-A20 15 Pin "D" connector. Use the following information to
make these connections:
110V and 220V Power Supply
V550-A20 Pin #
Ground
Pin 11
+5V
Pin 15
If no ground is available from another source, you can connect to the
ground terminal of the power supply. This grounds the shell/case.
Supplying
Power to Your
V550-A20
When you are using
Omron's local power
supply, make sure the
metal shell of the
connector is grounded.
Omron power supply (not UL Class 2)
S82S-0305
Summary of Contents for V550-A20
Page 1: ...i V550 A20 Operation Manual V550 A20 Bar Code Reader Operation Manual Cat No Q01BAZ2...
Page 5: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 26: ...12 V550 A20 Operation Manual Section 2 12 What to Do After Receiving the V550 A20...
Page 59: ......
Page 66: ...18 V550 A20 Operation Manual Section 5 18 Appendices...