43
V400-H101/201
User’s Manual
Sec
tio
n 4
Communications
Using the 2
DCR Configear
Section 4
System Settings
Communications Using the 2DCR Configear
The 2DCR Configear can be used to communicate with the Handheld 2D Code Reader.
■
Communication Setting
The following items can be set.
The default settings are indicated with an asterisk.
Operation is not possible when the port is connected.
Menu
Communication
Setting
Connect Button
Connects or disconnects
from the port.
Communication Log
Display Form
Selects the communication log display format
as either text format or hexadecimal.
Direct Command Input
Sends the input text string
to the Handheld 2D Code Reader.
Status display
Setting item
Settings
Port No.
COM1
*
to COM 9
Baud Rate
9,600
*
, 19,200, or 38,400
Parity
None
*
, odd, or even
Data Length
7 bits or
8 bits
*
Stop Bit
1sbit
*
or 2 bits
Header/Footer
Prefix
Send
None
*
, 02 <STX>, or 1B <ESC>
Receive
None
*
, 02 <STX>, or 1B <ESC>
Suffix
Send
03 <ETX>, 0A <LF>,
0D <CR>
*
, or 0D0A <CR+LF>
Receive 03 <ETX>, 0A <LF>,
0D <CR>
*
or 0D0A <CR+LF>
FCS
Send
ON or
OFF
*
Receive ON or
OFF
*
Same as Send
Sets the header, footer, and FCS for receiving to the same settings as for
sending.