![Omron STC-SBA503POE Product Specifications And User'S Manual Download Page 46](http://html1.mh-extra.com/html/omron/stc-sba503poe/stc-sba503poe_product-specifications-and-users-manual_742914046.webp)
No.13S094-05
46/59
STC-SCA503POE / STC-SBA503POE
Product Specifications and User’s Guide
9.11
Save and load the camera setting data
The camera has the camera setting including the factory default, load function.
The camera has below two camera settings.
Default: The factory default data (This data cannot change)
UserSet1: Changeable data
These camera settings load to the register in the RAM on the camera.
The camera settings saving and loading is controllable with “UserSetSelector” and “UserSetDefaultSelector”
parameters, and “UserSetLoad” and “UserSetSave” commands in UserSetControl category of GenICam.
The details of the parameters and the functions are in the table below:
GenICam parameters
UserSetSelector
Enumeration
type
Select “Default” or ”UserSet1”
UserSetLoad or UserSetSave process for the selected data.
UserSetDefaultSelector
Enumeration
type
Select which settings (“Default or UserSet1”) load automatically
when the camera power is on.
Selection saves automatically.
UserSetLoad
Command type The camera settings load from ROM to the register in RAM.
UserSetSave
Command type The camera settings at the register in RAM save to ROM.
The camera settings saving
The camera settings saving procedure
1. Selects “UserSet1” at UserSetSelector.
2. Executes UserSetSave.
When UserSetSave is executing,
the camera settings in the register at
RAM, save to ROM that is selected
at UserSetSelector
Caution:
UserSetSave command is only
available when “UserSet1” is selected
at UserSetSelector
ROM
UserSet1
ROM
Default
RAM
register
UserSetSelector
Selector