No.13S094-05
26/59
STC-SCA503POE / STC-SBA503POE
Product Specifications and User’s Guide
Exposure Timing with the Positive Polarity Trigger Signal
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 60 CLK.
Please input a trigger signal with more than 61 CLK pulse width.
Note 2: The exposure will start 8H after the rising edge of the trigger signal.
Exposure Timing with the Negative Polarity Trigger Signal
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 60 CLK.
Please input a trigger signal with more than 61 CLK pulse width.
Note 2: The exposure will start 8H after the rising edge of the trigger signal.
T1'
Input Trigger signal
Exposure time
Exposure time: T1' = T1 - 8 H
T1
60 CLK
Filtering *Note.1
Trigger signal
(With Photocoupler delay
Less than
15 useconds
T1
8H
T1'
Input Trigger signal
Exposure time
Exposure time:: T1' = T1 - 8 H
T1
Filtering *Note.1
Trigger signal
(With Photocoupler delay
Less than
15 useconds
T1
60 CLK
8H