![background image](http://html1.mh-extra.com/html/omron/stc-lbs132poe-swir/stc-lbs132poe-swir_product-specifications-and-users-manual_742897048.webp)
No.21S102-02
48/71
STC-LBS132POE-SWIR
Product Specifications and User’s Guide
11.14 Image Flip
The horizontal flip image can be selected by “ReverseX”.
The vertical flip image can be selected by “ReverseY”.
GenICam Parameters
ReverseX
IBoolean Type
Horizontal flip image ON / OFF selection
Selection: “False” (Horizontal flip is Off), “True” (Horizontal flip is On)
Default: “False” (Horizontal flip is Off)
ReverseY
IBoolean Type
Vertical flip image ON / OFF selection
Selection: “False” (Vertical flip is Off), “True” (Vertical flip is On)
Default: “False” (Vertical flip is Off)
11.15 Flat Field Correction Function
When using this function, the
unevenness of
black level of camera (DSNU) and shading on image that caused
by characteristics of lens (amount of through light difference at center and edge of lens) and characteristics of
light (
unevenness of sensitivity, PRNU) can be correct
.
When using this function, please follow below procedure after set exposure time (ExposureTime), analog gain
(AnalogGain), black level (BlackLevel).
Please proceed DSNU correction when change exposure time, analog gain or black level.
GenICam Parameters
FFCSelector
IEnumeration Type FFC function selection
Offset: DSNU correction
Gain: PRNU correction
Default: Gain
FFCEnable
IBoolean Type
FFC function ON / OFF selection
Selection: “True” (On): selected correction is applied image is
acquired,
“False” (Off): selected correction does not apply
image is acquired.
Default: False
FFCType [FFCSelector]
IEnumeration Type
FFC correction value acquiring method is displaying
Pixel: Correction value is acquiring each pixel
(DSNU correction)
Mesh: Correction value is acquiring each 8x8 pixels
(PRNU correction)
FFCAuto [FFCSelector]
IEnumeration Type
FFC auto correction process
Off: Stop correction process
Once: Start correction process
FFCValueStatus [FFCSelector]
IEnumeration Type
FFC correction result is displaying
“Success” is displaying when DSNU correction is
correctly done.
“Failure” is displaying when power is off or error
occurred while proceeding DSNU correction.
In this case, please do DSNU correction process again.