background image

S8BA-SBF

33

Safety Precautions

Warning Indications

Meaning of Product Safety Symbols

(for use of this product)

Provide safety measures outside the UPS to ensure 
safety in the entire system even if the UPS is damaged 
or an abnormality occurs due to an external factor. Not 
doing so may result in serious accidents due to 
incorrect operation.

(Wiring)

Do not short between the connector terminals.

Doing so may result in electric shock.

The battery unit's protection board may be damaged 
due to a short-circuit.

Connect each connection cable to the correct 
connected device.

Connect the terminal of each connection cable to the connector 
port with correct polarity.

Be sure to follow the connection procedure described in User's 
Manual (NUD-D18006A)

(When replacing the battery unit)

Dispose of or collect (recycle) the battery unit according 
to your own rules set for that purpose or as instructed by 
laws and regulations.

Do not dispose of it in fire. Otherwise, it could explode.

(for installation and connection)

Pay attention to the weight and balance when carrying 
the unit, and install it in a solid and stable location.

Do not drop the battery unit and do not expose it to 
strong impact. Dropping the unit may result in injury or 
fire.

If you drop the unit, have it inspected and repaired. For 
repairs, contact our sales personnel.

Keep plastic package bags out of reach of children.

Children may suffocate if they place their heads into 
plastic bags.

Be sure to connect the input power supply of the unit to a 
DC power supply device having a rated voltage (24 
VDC), or a battery power feed system.

The input voltage ranges for the UPS are as shown 
below. Check that the output voltage of the DC power 
supply device connected to the input terminal of the UPS is within 
any of the voltage ranges below.

Voltage range: 23 to 28 V DC

Connecting to a DC or AC power supply device with a different 
voltage may result in malfunction in or damage to the UPS, or 
cause a fire.

When an abnormality (unusual sound or smell) occurs, 
turn OFF the unit’s ‚”Power‚” switch to stop the output, 
and stop the supply of commercial power.
To make an emergency stop, move the rotary switch to 
"BATT REP", and when the LED changes from a fast blink to a slow 
blink, shut off the input power.

When performing maintenance on the connected devices, follow 
the above instructions to ensure safety.

When installing the input cable, make sure to perform the 
connection as specified.
Make sure to stop the primary power supply before 
connecting the unit to the input power supply terminal.

When connecting a cable to the terminal block, use a 
cable that complies with the input current specification 
of the UPS. Failure to do so may result in electric 
shock or ground fault.

Do not disassemble, repair, or modify the unit.

Doing so may cause an electric shock or a fire.

Do not install the unit in other than specified orientations.

Dropping or toppling the unit may cause injury.

If you install the unit in an orientation other than 
specified, the internal temperature may rise, 
eventually damaging the UPS or deteriorating the battery.

Warning

Indicates a potentially hazardous 
situation that, if not avoided, could 
result in serious injury or death. 
Additionally there may be significant 
property damage.

Caution

Indicates a potentially hazardous 
situation that, if not avoided, could 
result in minor or moderate injury or 
property damage.

Precautions for 

Safe Use

Supplementary comments on what to 
do or avoid doing, to use the product 
safely.

Precautions for 

Correct Use

Supplementary comments on what to 
do or avoid doing, to prevent failure to 
operate, malfunction or undesirable 
effect on product performance.

General inhibition
Notice prohibiting an unspecified general action.

General instruction
Notice instructing an unspecified general action.

Do-not-disassemble prohibition
Notice prohibiting disassembly because 
disassembling the device may cause such an 
accident as an electric shock.

Prohibition of use in locations subject to water 
such as a bathroom and shower room
Notice prohibiting installation of the device in 
locations subject to water, because if a device not 
made water-proof is used in such locations, injury 
may occur due to an electric leak.

Do-not-touch prohibition
Indicates the possibility of injuries by touching 
the specific portion of the device under specific 
conditions, prohibiting touching of the device.

Explosion alert
Notice alerting the user to the possibility of 
explosion under certain conditions.

 

Warning

 

Caution

廢電池請回收

Summary of Contents for S8BA LF Series

Page 1: ...Model Number Legend Use the following format to place an order Ordering Information Main body Uninterruptible Power Supply UPS 16 7 A 400 W for use as a UL compliant device Communication cable Replac...

Page 2: ...play cancellation at a load equal to or below the rated capacity normal operation backup operation Battery Type Lithium ion battery Rated voltage 14 4 VDC Rated capacity 1600 mAh 1 parallel 1600 mAh 2...

Page 3: ...ad lines V V 3 DC input terminal block Connect to input lines V V 4 GR terminal Ground this terminal to less than 100 to improve noise resistance and prevent electrical shock 5 USB port Connect to a U...

Page 4: ...0 W S8BA 24D24D240LF 240 W S8BA 24D24D360LF 360 W S8BA 24D24D480LF 480 W No Name Function 11 DIN rail mounting hook Hook the UPS on the DIN rail 12 DIN rail mounting groove Groove for positioning the...

Page 5: ...wire Twisted pair 0 5 mm2 AWG AWG20 10 A Solid wire Twisted pair 0 75 mm2 AWG AWG16 15 A Solid wire Twisted pair 1 25 mm2 AWG AWG14 20 A Solid wire Twisted pair 2 0 mm2 AWG AWG12 Temperature rating f...

Page 6: ...the UPS is stopped after the time period specified in advance has elapsed Remote ON OFF signal Remote ON OFF signals can be used to start and stop the UPS by using either an externally connected cont...

Page 7: ...e with no problems even if the rated capacity of the UPS is larger than the rated capacity of the switching power supply Switch mode power supply capacity UPS internal power consumption Internal power...

Page 8: ...the total capacity of the connected devices 3 Calculate the initial value of the backup time for the total capacity of the connected devices from the graph below Graph of backup time graph of initial...

Page 9: ...20 0 Ambient temperature C Load rate A For standard mounting B For face up mounting stationary mounting A C B 0 10 20 30 40 50 60 120 100 80 60 40 20 0 Ambient temperature C Load rate A For standard m...

Page 10: ...s During power failure Power switch Battery level UPS output Indication in the status display Beeper UPS operating mode BU signal OUT BL signal OUT BS signal IN Normal operation Backup operation ON ON...

Page 11: ...2 In normal operation the output stops when the input protection fuse blows out Dimensions Unit mm Main body 0 20 40 60 80 100 0 20 40 60 80 100 120 In backup operation Output current Output voltage 1...

Page 12: ...er 2012 R2 2012 Windows Storage Server 2008 R2 2008 RS232C USB Simple Shutdown Software You can execute computer shutdown and UPS auto stop when an input power problem occurs power failure etc You can...

Page 13: ...imary power supply before connecting the unit to the input power supply terminal When connecting a cable to the terminal block use a cable that complies with the input current specification of the UPS...

Page 14: ...ct with water If you drop the unit stop using it Doing so may cause an electric shock or a fire Doing so may cause an abnormal heating smoke rupture or fire on the battery If the unit becomes wet or i...

Page 15: ...nside the battery may melt the gas exhaust valve or protection mechanism may be damaged or the electrolyte may catch fire and it may result eventually in abnormal heating smoke rupture or fire Do not...

Page 16: ...main body and use the UPS in an operating condition below the derating curve During machining work for mounting make sure that no metal scrap goes into the product The heat dissipation of the UPS may...

Page 17: ...ll machine conform to EMC standards Applicable EMC Electromagnetic Compatibility standards are as follows EMS Electromagnetic Susceptibility EN 61000 6 2 EMI Electromagnetic Interference EN 61000 6 4...

Page 18: ...xpressly approved by the party responsible for compliance could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class A digi...

Page 19: ...he USB RS 232C I O port installed in the UPS Two types of batteries are selectable for the 480W allowing the ideal backup time to be realized A wide lineup culminating in the 960W makes it possible to...

Page 20: ...Communication cable Input voltage Output voltage Output current capacity Model number 24 VDC 24 VDC 20 A 480 W S8BA 24D24D480SBF 40 A 960 W S8BA 24D24D960SBF Rated voltage Rated capacity Weight Model...

Page 21: ...cteristics 6 min constant power rated load The backup time can be set from the mode selection backup operation time selection switch or the shutdown software Environme nt Operating environment tempera...

Page 22: ...han specified time 4 Conditions With rated loads connected at a rated input voltage and at a full battery charge 5 Conditions With rated loads connected at a rated input voltage and at maximum battery...

Page 23: ...ck 6 Battery communication port 3 Battery connection terminal block 7 Mode selection Backup time setting switch 4 LED indicators 8 RS232C USB port DC ON LED BATT LED ALERT LED Positive terminal Negati...

Page 24: ...S8BA SBF 24 Rear view S8BA 24D24D480SBF S8BA S480L S8BA 24D24D960SBF S8BA S960L 9 9 No Name 9 DIN rail hook 9 9 No Name 9 DIN rail hook...

Page 25: ...and recommended cable sizes see the following table 20 A 40 A Connectable sizes Cable Solid wire 0 2 to 10 mm2 0 75 to 16 0 mm2 Stranded wire 0 2 to 6 mm2 AWG AWG 8 to 24 AWG 6 to 18 Stripped cable le...

Page 26: ...ied in advance has elapsed Remote ON OFF signal Remote ON OFF signals can be used to start and stop the UPS by using either an externally connected contact or the ON OFF status of the open collector c...

Page 27: ...e with no problems even if the rated capacity of the UPS is larger than the rated capacity of the switching power supply Switch mode power supply capacity UPS internal power consumption Internal power...

Page 28: ...e backup time for the total capacity of the connected devices from the graph below Graph of backup time graph of initial values for products that have not been used at 25 C The backup time becomes sho...

Page 29: ...Contact mounting Less than 15 mm space between the left and right 0 10 20 30 40 50 60 100 80 60 40 20 0 Ambient temperature C Load rate 0 10 20 30 40 50 60 100 80 60 40 20 0 Ambient temperature C Load...

Page 30: ...ge 26 Overcurrent protection curve 480 W 960 W Durling power failure Input power supply Output from UPS UPS operating mode Normal operation Backup operation BU signal OUT BL signal OUT BS signal IN Ba...

Page 31: ...1 Dimensions Unit mm Control unit Battery unit S8BA 24D24D480SBF 124 9 5 31 99 4 44 111 4 S8BA 24D24D960SBF 9 5 52 124 111 4 31 99 4 111 4 9 5 30 7 80 124 99 4 S8BA S480L 111 4 9 5 150 124 30 7 99 4 S...

Page 32: ...er 2012 R2 2012 Windows Storage Server 2008 R2 2008 RS232C USB Simple Shutdown Software You can execute computer shutdown and UPS auto stop when an input power problem occurs power failure etc You can...

Page 33: ...ch to BATT REP and when the LED changes from a fast blink to a slow blink shut off the input power When performing maintenance on the connected devices follow the above instructions to ensure safety W...

Page 34: ...or more above the top and below the bottom Do not connect the RS232C USB port or the CONTACT port to a LAN device using a LAN cable Connection to a LAN device may result in malfunction in or damage t...

Page 35: ...he input terminal block and the output terminal block of the UPS Doing so may result in electric shock Do not insert metal objects into the battery connectors Do not short between the connector termin...

Page 36: ...is left unused in the above state for 3 months or longer the battery goes into overdischarge state and the backup time may become shorter or the battery may become unusable Storing Storing the battery...

Page 37: ...schedule and frequency Applicable directives EMC Directives Low Voltage Directives Principles regarding conformance OMRON electronic devices that comply with EC Directives also conform to the related...

Page 38: ...f radio interference occurs the user may be required to take appropriate measures Conformance to UL This product must be installed within a control panel with an internal heater or other unit to prote...

Page 39: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Page 40: ...2356 81 388 Contact www ia omron com Kyoto JAPAN OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 Fax 65 6835 2711 OMRON CHINA...

Reviews: