Note
Caution
& !"#"
Section 2-8
Connec-
i
Signal name
Abbrevi-
i
Signal direction
tor pin #
g
ation
Input
Output
1
Frame ground
FG
---
---
2
Send data
SD (TXD)
---
Yes
3
Receive data
RD (RXD)
Yes
---
4
Request to send
RS (RTS)
---
Yes
5
Clear to send
CS (CTS)
Yes
---
6
+5V 150mA Max. (ST211(B)-EV
)
100mA Max. (ST121(B)-EV
)
+5 V
---
Yes
9
Signal ground
SG (GND)
---
---
1. FG is not connected internally in the NT600S.
2. Unlisted pins are not used.
For cable parts and the wiring method, refer to APPENDIX E Method for Making
the Cable for Connection to the PC/Host (page 264).
Connecting to the Host Computer
Use a cable that is compatible with the RS-232C connector of the host to connect
the NT600S and the host.
In the example shown here, the cable connects the 9-pin connector of the NT600S
and 25-pin connector of the host. If the host has a 9-pin RS-232C connector, use
an RS-232C cable with 9-pin connectors at both ends.
NT600S
25-pin
connector
Host Interface connector
(RS-232C, 9-pin type)
9-pin
connector
RS-232C cable
Turn off the NT600S power supply when connecting or disconnecting connec-
tors.
After connecting a communication cable, always secure it with the screws.
Check that the current capacity of the equipment to be supplied is within 150 mA
before using the +5V output of pin No.6. Otherwise, the product may malfunc-
tion.
The current capacity of +5 V output of NT600S is:
+5 V
5%, 150 mA max. with ST211(B)-EV
, and
+5 V
5%, 100 mA max. with ST121(B)-EV
.
Summary of Contents for NT-series
Page 1: ...NT series Programmable Terminal Operation Manual Cat No V022 E3 1 ...
Page 2: ... ...
Page 4: ... ...
Page 9: ... PRECAUTIONS ...
Page 14: ... ...
Page 36: ... ...
Page 166: ... ...
Page 254: ... 0 4 4 5 4 5 6 5 4 4 5 5 7 5 5 6 5 ...
Page 267: ... ...
Page 281: ... 2 C500 LK201 and C200H LK201 V1 only ...
Page 311: ... ...
Page 317: ... ...