[ MEMORY SWITCH MENU (1/2) ]
Support Tool Mode
NT600S
EXIT
SAVE
EXIT
NEXT
PAGE
- $0& 1 . -
Section 3-6
4-6-4
Setting the RS-232C Communication Conditions
When connecting the NT600S to the host by the RS-232C method, set the follow-
ing communication conditions.
Item
Setting
Factory-Setting
RS-232C Speed
2400/4800/9600/19200bps
(to be set to the same value as set for the Host)
2400bps
Data bit length
7 bits/8 bits
8 bits
Stop bit length
1 bit/2 bits
1 bit
Parity bit
Even/odd/none
None
Flow control
RS/CS control
XON/XOFF control
None
None
Select the required menu option from the System Menu by following the procedure
given below.
Select “Maintenance Mode”.
Select “Memory Switches”.
Press “NEXT PAGE”.
If the RS-232C has been se-
lected, the host link speed set-
ting does not make any effect.