Section 5-5
Program operation
(1) If PT operating status (contact 11215) is turned OFF (0) and battery (con-
tact 11213) is turned ON (1), “1” (NT600S stop, low battery voltage) is trans-
mitted to DM0001.
(2) If PT operating status (contact 11215) is turned OFF (0) and battery (con-
tact 11213) is turned OFF (0), “2” (NT600S stop, normal battery voltage) is
transmitted to DM0001.
(3) If PT operating status (contact 11215) is turned ON (1) and battery (contact
11213) is turned ON (1), “3” (NT600S running, low battery voltage) is trans-
mitted to DM0001.
(4) If PT operating status (contact 11215) is turned ON (1) and battery (contact
11213) is turned OFF (0), “4” (NT600S running, normal battery voltage) is
transmitted to DM0001.