21
3-4 What has changed
3-4-1 Memory Link Commands
This summarizes the points that need to be given attention when switching over from
NT31/631 series to NS series Memory Link.
Memory structure inside PT differs, so the structure of Memory Link commands has
changed as well.
■
Memory structure inside PT
NT31/631 series
NS series
Contact
point
Contact
point
$B0 to 65535
PT memory
channel
common
0000 to 9999
channel $W0
to
65535
Memory table
Number memory table
Character string memory
table
bit memory table
none
Battery backup
Is performed
Is not performed
■
Memory Link command
NT31/631 series
NS series
RM
Read-out PT memory
Read-out PT memory ($W)
RB
Read-out bit memory table
Read-out PT memory ($B)
RN
Read-out number memory table
-
RS Read-out
character
string
memory table
-
WM
Write to PT memory
Write to PT memory ($W)
WB
Write to bit memory table
Write to PT memory ($B)
FR
Read-out display data comment
-
PT
Read-out system conditions
-
WN
Write to number memory table
-
WS
Write to character string memory
table
-
FM
Fill PT memory
Fill PT memory ($W)
FB
-
Fill PT memory ($B)
CN Clear
number
memory
table
-
CS
Clear character string memory
table
-
CB
Clear bit memory table
-
ST
Touch switch input notice
-
SN Number
input
notice
-