background image

PC motion controller

81

MECHATROLINK-II, analog output module (AN2910)

MECHATROLINK-II repeater

MECHATROLINK-II servo drive interface unit

MECHATROLINK-II, frequency inverter interface units

Items

Specifications

Appearance

Model

JEPMC-AN2910

Number of output 
channels

2

Output voltage range

-10 V  to  +10 V

Max. allowable
load current

± 5 mA (2 k

Ω

)

Data format

Binary, -32000 to +32000

Output delay time

1 ms

Error

± 0.2% F.S. (at 25 °C), ± 0.5% F.S. (at 0 °C to 60 °C)

External power supply

24 VDC (20.4 VDC to 26.4 VDC), 120 mA max.

Weight

300 g

Items

Specifications

Appearance

Model

JEPMC-REP2000

Communication type

MECHATROLINK-II

Cable length

Between controller and repeater: 50 m, after repeater: 50 m

Max. connected 
stations

Total stations on both sides of repeater: 30
(limited to the max. number of connectable stations of the controller (e.g., 21 stations for the MP2300 series)

Restrictions

Between controller and repeater
-  Total cable length 

  30 m: 

15 stations max. including I/O and servo, etc.

-  30 m < total cable length 

≤ 

 50 m:  14 stations max. including I/O and servo, etc.

After repeater:
-  Total cable length 

  30 m: 

16 stations max. including I/O and servo, etc.

-  30 m < total cable length 

≤ 

 50 m:  15 stations max. including I/O and servo, etc.

Power supply

24 VDC, 100 mA

Weight

340 g

Dimensions (mm)

30x160x77 (HxWxD)

Item

Details

Type

JUSP-NS115

Applicable servo drive

SGDH-

@@@

E models (version 38 or later)

Installation method

Mounted on the SGDH servo drive side: CN10.

Basic 
specifications

Power supply method

Supplied from the servo drive control power supply.

Power consumption

2 W

MECHATROLINK -II 
communications

Baud rate/transmission cycle

10 Mbps / 1 ms or more. MECHATROLINK-II communications 

Command format

Operation specification

Positioning using MECHATROLINK-I/II communications.

Reference input

MECHATROLINK-I/II communications
Commands: position, speed, torque, parameter read/write, monitor output

Position control 
functions

Acceleration/deceleration method Linear first/second-step, asymmetric, exponential, S-curve
Fully closed control

Position control with fully closed feedback is possible.

Fully closed 
system 
specifications

Encoder pulse output in the 
servo drive

5 V differential line-driver output (complies with EIA Standard RS-422A)

Fully closed encoder pulse signal  A quad B line-driver
Maximum receivable frequency 
for servo drive

1 Mpps

Power supply for fully closed 
encoder

To be prepared by customer.

Input signals in the 
servo drive

Signal allocation 
changes possible

Forward/reverse run prohibited, zero point return deceleration LS
External latch signals 1, 2, 3
Forward/reverse torque control

Internal functions

Position data latch function

Position data latching is possible using phase C, and external signals 1, 2, 3

Protection

Parameters damage, parameter setting errors, communications errors, 
WDT errors, fully closed encoder detecting disconnection

LED indicators

A: Alarm, R: MECHATROLINK-I/II communicating

Item

Details

Type

SI-T/V7

SI-T

Applicable inverter

CIMR-V7 / 3G3-MV
(firmware 5740 or newer)

CIMR-G7 / CIMR-F7
(firmware 656x/for G7 / 4011 or newer for F7)

Contact your OMRON sales office for information about firmware compatibility

Installation method

Mounted on the inverter

Power supply

Supplied from the inverter

MECHATROLINK-II communications

10 MHz, 0.5 ms to 8 ms for MECHATROLINK-II

Operation

Read and write registers, read monitors, inverter operation, speed reference, torque reference 
(G7/F7 only).

Inputs and outputs

The inputs and outputs in the inverter can be read and set by the MLII master

Connectors

ML-II bus connector. DPRAM connector for the inverter

Switches

Rotary switch for ML-II address (low byte)
Dip switch for: ML-II address (high bit). ML-II/ML-I selection. 17 byte/32 byte data length selection.

NS115

Y203-EN2-02-Katalog.book  Seite 81  Mittwoch, 24. Mai 2006  2:22 14

Summary of Contents for MECHATROLINK-II MP2100

Page 1: ...ration NS115 S W 1 S W 2 A R C N 6 A C N 6 B C N 4 CHARGE POWER SERVOPACK SGDH 200V Ver CN3 CN1 CN2 NS115 S W 1 S W 2 A R C N 6 A C N 6 B C N 4 CHARGE POWER SERVOPACK SGDH 200V Ver CN3 CN1 CN2 CHARGE POWER SERVOPACK SGDH 200V Ver CN3 CN1 CN2 NS115 S W 1 S W 2 A R C N 6 A C N 6 B C N 4 CHARGE POWER SERVOPACK SGDH 200V Ver CN3 CN1 CN2 NS115 S W 1 S W 2 A R C N 6 A C N 6 B C N 4 C N 1 C N 2 RUNTX 1 2...

Page 2: ...2 to 300 ms Integral multiple of MECHATROLINK communication cycle User drawings functions and motion programs Startup drawings DWG A Interrupt processing drawings DWG I High speed scan process drawings DWG H Low speed scan process drawings DWG L Number of steps User functions Motion programs Revision history of drawings and motion programs Security function for drawings and motion programs 64 draw...

Page 3: ...C pulse Yes ZERO signal Yes DEC1 ZERO signal Yes Phase C pulse Yes Only phase C pulse Yes POT and phase C pulse Yes POT Yes Home limit switch and phase C pulse Yes HOME Yes NOT and phase C pulse Yes NOT Yes INPUT and phase C pulse Yes INPUT Yes Applicable servo drives SGDH E OY NS115 Applicable frequency inverters Varispeed V7 F7 G7 with MECHATROLINK II Interface for inverter s version supported c...

Page 4: ... rating is 100 mA per point sink mode output NPN Signal connection method Connector FCN360 series Module power supply 24 VDC 20 4 V to 28 8 V Rated current 0 5 A Inrush current 1 A Weight 590 g Items Specifications Appearance Model JEPMC PL2900 Number of input channels 2 Functions Pulse counter notch output registration input Pulse input method Sign 1 2 multipliers A B 1 2 4 multipliers UP DOWN 1 ...

Page 5: ... input MECHATROLINK I II communications Commands position speed torque parameter read write monitor output Position control functions Acceleration deceleration method Linear first second step asymmetric exponential S curve Fully closed control Position control with fully closed feedback is possible Fully closed system specifications Encoder pulse output in the servo drive 5 V differential line dri...

Page 6: ...8 4 tapped holes M4 121 0 2 111 0 2 Mounting hole diagram 108 4 5 4 5 111 120 121 130 4 5 4 5 4 5 152 RUN TX 1 2 3 4 5 6 7 8 120 DDI 343 30 C N 1 C N 2 4 5 161 152 44 RUN TX 1 2 3 4 5 6 7 8 120 DDI 343 30 89 8 79 24 CN6A Units mm Approx weight 0 2 kg NS115 S W 1 20 128 142 100 2 S W 2 A R C N 6 A C N 6 B C N 4 Name plate CN6B CN4 FG terminal Connector to SERVOPACK M4 ...

Page 7: ...ers JEPMC W6003 10 20 meters JEPMC W6003 20 30 meters JEPMC W6003 30 MECHATROLINK II terminator Terminating resistor JEPMC W6022 MECHATROLINK II interface unit For Sigma II series servo drives Firmware version 38 or later JUSP NS115 For Varispeed V7 inverter for inverter version support contact your OMRON sales office SI T V7 For Varispeed F7 G7 inverter for inverter version support contact your O...

Page 8: ...t of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No I35E EN 01 ...