Safety Precautions

Be sure to read the precautions for all models in the website at the following URL: http://www.ia.omron.com/.

Warning Indications

Meaning of Product Safety Symbols

 

!

CAUTION

Doing so may occasionally result in minor injury due 
to electric shock. Do not touch the Relay while the 
power supply is ON, except for the adjustment knob.

There is a risk of minor electrical shock, fire, or device 
failure. Do not allow any pieces of metal, conductors, or 
cutting chips that occur during the installation process to 
enter the product.

Explosions may cause minor injuries. Do not use the 
product in locations with inflammable or explosive 
gases.

There is a risk of minor electrical shock, fire, or device 
failure. Do not disassemble, modify, repair, or touch 
the inside of the product.

Use of the product beyond its life may result in 
contact welding or burning. Make sure to consider the 
actual operating conditions and use the product 
within its rated load and electrical life count. The life 
of the output relay varies significantly with the switching 
capacity and switching conditions.

If the Relay is used with incorrect wiring, fire may 
occasionally occur, possibly resulting in physical 
damage. Check the wiring for mistakes before you 
turn ON the power supply.

If the Relay fails, monitoring and alarm outputs may 
fail to operate. This may result in physical damage to 
the facilities, equipment, or other devices that are 
connected to it. To reduce this risk, inspect the Relay 
regularly. To maintain safety in the event of 
malfunction of the Relay, take appropriate safety 
measures, such as installing a monitoring device on a 
separate line.

If the wire insertion length is insufficient, fire may 
occasionally occur, possibly resulting in physical 
damage. Insert the wires all the way to the back.

The terminal block may be damaged if you insert a 
flat-blade screwdriver in the release hole with 
excessive force. Insert the flat-blade screwdriver into 
the release holes with a force of 15 N or less.

 CAUTION

Indicates a potentially hazardous 

situation which, if not avoided, may result 

in minor or moderate injury or in property 

damage.

Precautions for 

Safe Use

Supplementary comments on what to do 

or avoid doing, to use the product safely.

Precautions for 

Correct Use

Supplementary comments on what to do 

or avoid doing, to prevent failure to 

operate, malfunction, or undesirable 

effects on product performance.

Used to warn of the risk of electric shock under 

specific conditions.

Used for general prohibitions for which there is 

no specific symbol.

Used to indicate prohibition when there is a risk 

of minor injury from electrical shock or other 

source if the product is disassembled.

Used for general mandatory action precautions 

for which there is no specified symbol.

Summary of Contents for K8DT-AS Series

Page 1: ...ommercially available CT do not exceed the overload capacity of the K8DT AS2 Options Order Separately Front Cover Refer to Safety Precautions on page 10 Refer to page 9 for commonly asked questions Fo...

Page 2: ...DC Approx 5 Direct input Continuous input at 120 of maximum input 1 s at 150 100 mA AC DC I2 COM 10 to 100 mA AC DC Approx 1 Direct input 500 mA AC DC I3 COM 50 to 500 mA AC DC Approx 0 2 Direct input...

Page 3: ...Wire insertion force 8 N max for AWG20 wire Screwdriver insertion force 15 N max Wire stripping length 8 mm Ferrule length 8 mm Recommended flat blade screwdriver XW4Z 00B Omron SZF 0 4 2 5 Phoenix Co...

Page 4: ...copper wires with a rating of 75 C or an equivalent rating Inside Inside 1 Current Input AS1 2 Output C Relay Output T Transistor Output 3 Power Supply Voltage A 100 to 240 VAC D 24 VAC DC No polarit...

Page 5: ...1 s Power supply voltage Contacts 11 12 Set value Alarm indicator Lit Contacts 11 14 or transistor output Input Delay time 250 ms reference value Terminal block See note Terminal block See note Curren...

Page 6: ...itch cover to set the DIP switch Keep the DIP switch cover closed while the power supply to the Relay is ON Model Setting range Input type Wiring connections K8DT AS1 2 to 20 mA AC DC Direct input I1...

Page 7: ...et Value SV of 50 and Overcurrent Operation Operation will be at 100 A and resetting at 90 A when the hysteresis HYS is set to 10 Operating Time The operating time is set using the operating time knob...

Page 8: ...3 1 7 1 7 9 3 76 Two M5 screw holes or two 5 5 dia holes OMRON CT K8AC CT200L Mounting Hole Dimensions Note The OMRON Current Transformer CT is designed to be used with the K8DT AS3 Use terminals k an...

Page 9: ...ely 30 A The startup current will exceed the overload capacity rating 150 for 1 s of the K8DT AS1 and K8DT AS2 and result in failure of the Relay To monitor the motor load use the K8DT AS3 Overload ca...

Page 10: ...ails monitoring and alarm outputs may fail to operate This may result in physical damage to the facilities equipment or other devices that are connected to it To reduce this risk inspect the Relay reg...

Page 11: ...ck the wiring before you supply power to the product 22 Do not install the product immediately next to heat sources 23 Perform periodic maintenance 24 Do not wire anything to the release holes 25 When...

Page 12: ...e flat blade screwdriver from the release hole Checking Connections After the insertion pull gently on the wire to make sure that it will not come off and the wire is securely fastened to the terminal...

Page 13: ...n and other factors There is basic insulation between the power supply terminals and input terminals There is basic insulation between the power supply terminals and output terminals There is basic in...

Page 14: ...MEMO 14...

Page 15: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Page 16: ...9 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Kyo...

Reviews: