6. Zero Limit Setting
Zero limit setting enables the K3TJ to display zero for any value less than the set value. This is effective if the user needs to have the K3TJ
display zero instead of a negative value or the user needs to have the K3TJ display zero for the minimum input range value. The setting range is
from 00 to 99. When no zero limit is set,
off
will be displayed.
Use the Up or Down Key to input the
zero limit value. The displayed value
will increase automatically if the Up Key
is pressed for 1 s or more and will de-
crease automatically if the Down Key is
pressed for 1 s or more.
Up Key or
Down Key
1
3
4
5
6
7
8
2
OFF
ON
Set parameter selector pin 6 to ON to set
the zero limit.
After setting the zero limit, set parame-
ter selector pin 6 to OFF to complete
the zero limit setting.
1
3
4
5
6
7
8
2
OFF
ON
Display
Zero limit setting
99
to
00
Zero limit setting range
off
No zero limit (factory set)
Zero Limit Setting Range
Display
Zero limit
setting
value
Input
7. Step Display Setting
Step display setting is used to change the step of the displayed rightmost digit changes. This setting is effective if the input signal repeatedly
displays
999
and
1000
and is difficult to read. The following table shows the step display patterns.
Use the Up or Down Key to select the
display pattern.
Up Key or
Down Key
1
3
4
5
6
7
8
2
OFF
ON
Set parameter selector pin 7 to ON to set
the step display.
After selecting the display pattern, set
parameter selector pin 7 to OFF to
complete the step display setting.
1
3
4
5
6
7
8
2
OFF
ON
Display
Step display pattern
1
No step display (factory set)
2
With every two digits
5
With every five digits
10
With every ten digits (the rightmost digit is fixed to
0)
Step Display Parameter
The display step of the rightmost digit can be selected.
1
2
3
4
5
6
7
8
9 10 11 12 13 14
0
0
2
4
6
8
10
12
14
5
10
15
0
10
Input value
2-digit step
5-digit step
Fixed to be zero
D
isp
la
ye
d
va
lu
e
0