K3TJ
K3TJ
11
4. Decimal Point Setting
The decimal is set to the desired position.
Use the Up or Down Key to change the
decimal point position.
Up Key or
Down Key
1
3
4
5
6
7
8
2
OFF
ON
Set parameter selector pin 4 to ON to set
the decimal.
After changing the decimal point, set
parameter selector pin 4 to OFF to
complete the new decimal point set-
ting.
1
3
4
5
6
7
8
2
OFF
ON
Display
Decimal point
0000
No decimal point (factory-set)
000.0
Next to 10
1
digit on the left
00.00
Next to 10
2
digit on the left
0.000
Next to 10
3
digit on the left
Note:
In the case of a range of --0.001 to --0.999,
-.001
to
-.999
will
be displayed.
5. Average Process Setting
There are two ways to input signals: the simple average processing method and the movement average processing method.
In the simple average processing method, the mean value is displayed after sampling n times. This method is effective when the user requires a
long display refresh period.
In movement average processing method, the sampling data obtained from sampling n times including the present sampling operation is aver-
aged and displayed. This method is effective for removing the periodical noise overlapped with the input signals.
Use the Up or Down Key to change the
average processing method.
Up Key or
Down Key
1
3
4
5
6
7
8
2
OFF
ON
Set parameter selector pin 5 to ON to set
the average processing.
After selecting the average processing
method, set parameter selector pin 5 to
OFF to complete the average process
setting.
1
3
4
5
6
7
8
2
OFF
ON
Display
Average processing
1
No average processing is possible (factory set)
a- 2
Simple average processing by sampling twice
a- 4
Simple average processing by sampling four times
a- 8
Simple average processing by sampling eight
times
b- 2
Movement average processing by sampling twice
b- 4
Movement average processing by sampling four
times
b- 8
Movement average processing by sampling eight
times