background image

K3TJ

K3TJ

15

Precautions

Mounting

Recommended panel thickness is 1 to 3.2 mm.

Mount the K3TJ by attaching the mounting bracket supplied as an
accessory from the rear of the K3TJ. Turn each mounting screw
clockwise and tighten it to a torque of 5 kgf

$

cm (0.49N

$

m).

Mount the K3TJ as horizontally as possible.

Never use the K3TJ in locations where corrosive gas (particularly
sulfuric or ammonia gas) exists.

Avoid use of the K3TJ in locations subject to severe shock or vibra-
tion, excessive dust, or excessive moisture.

Select mounting locations where the ambient operating tempera-
ture is --10

#

C to 55

#

C.

Others

When selecting parameters or making settings, the front panel cov-
er should be removed. Do not touch parts other than the DIP switch
and keys with your hand or a metal object, especially when the K3TJ
is turned ON.

Summary of Contents for K3TJ

Page 1: ...htness can be adjusted Conforms to the EMC standard EN61010 1 IEC1010 1 uC Ordering Information DC Voltage Input Model Voltage measurement range Display color Supply voltage g g p y 100 to 240 VAC 24...

Page 2: ...nce Malfunction 10 to 55 Hz 0 5 mm single amplitude for 10 minutes each in X Y and Z directions Destruction 10 to 55 Hz 0 75 mm single amplitude for 2 hours each in X Y and Z directions Shock resistan...

Page 3: ...panel meets the requirements of IP50 instead Measuring Ranges Measuring range Input impedance Reliability Max permissible continuous load Voltage DC 1 to 5 VDC 1 M 0 1 rdg 1 digit 250 V g 0 to 5 VDC 1...

Page 4: ...iver into the groove on the bottom of the front panel and pull the front panel off The following is seen after the front panel is removed Parameter selector Up Key Down Key 1 34 5 6 7 8 2 ON No Name P...

Page 5: ...o 1000 0 to 10 VDC input DC Current Input Model Input range Display 4 to 20 mA DC input 0 to 1000 1000 0 max min Display Input Adjust the display shift and scaling for the K3TJ while applying an actua...

Page 6: ...the display To change the value to 0 use the Down Key The displayed value will increase automatically if the Up Key is pressed for 1 s or more and will decrease automatically if the Down Key is press...

Page 7: ...er selector pin 3 to ON at which time the display will not change but a scaling adjustment will be possible After 1200 is displayed set parameter selector pin 3 to OFF to complete the scaling adjustme...

Page 8: ...gntimes This methodis effectivewhentheuserrequiresa long display refresh period Inmovement averageprocessing method the samplingdata obtainedfrom samplingn times including thepresent samplingoperation...

Page 9: ...mit setting range off No zero limit factory set Zero Limit Setting Range Display Zero limit setting value Input 7 Step Display Setting Step display setting is used to change the step of the displayed...

Page 10: ...alue stored in the non volatile memory has been corrupted Execute display shift again according to the display shift adjustment procedure e 12 The scaling value stored in the non volatile memory has b...

Page 11: ...ections 24 VDC HOLD GND GND 0 to 10 VDC 0 to 5 VDC 1 to 5 VDC 4 to 20 mA DC INPUT POWER 3 2 1 4 5 6 7 8 9 100 to 240 VAC Note Terminals 3 and 6 are connected internally The power supply terminals are...

Page 12: ...le Never use the K3TJ in locations where corrosive gas particularly sulfuric or ammonia gas exists Avoid use of the K3TJ in locations subject to severe shock or vibra tion excessive dust or excessive...

Page 13: ...n Phone 06 949 6012 Fax 06 949 6021 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No N080 E1 1C In...

Reviews: