background image

8

AC  Servo Systems

Junma MECHATROLINK-II Servo Drive 

Note:

*1. Value without external regeneration unit 

Servomotor / Servo Drive Combination

Junma Servomotor

Junma servo drive

Voltage  Rated Torque Capacity Model without brake

Model with brake

MECHATROLINK-II

Pulse Control

SJME- (3000 min

-1

)

200 V

0.318 Nm

100 W

SJME-01AMB41-OY

SJME-01AMB4C-OY

SJDE-01ANA-OY

SJDE-01APA-OY

0.637 Nm

200 W

SJME-02AMB41-OY

SJME-02AMB4C-OY

SJDE-02ANA-OY

SJDE-02APA-OY

1.27 Nm

400 W

SJME-04AMB41-OY

SJME-04AMB4C-OY

SJDE-04ANA-OY

SJDE-04APA-OY

2.39 Nm

750 W

SJME-08AMB41-OY

SJME-08AMB4C-OY

SJDE-08ANA-OY

SJDE-08APA-OY

Servo Drive Type Designation

SJDE - 02  A  N  A - OY

JUNMA servo drive 

Applicable servomotor capacity

Power supply voltage

Control Interface specification

Code

A: 200 VAC

Design revision
A: Standard

N: MECHATROLINK-II
P: Pulse train input

01
02
04
08

Output (W)

100
200
400
750

OMRON YASKAWA Motion Control BV

Servo Drive Specifications

Servo Drive Type

SJDE- 

@

01ANA-OY

02ANA-OY

04ANA-OY

08ANA-OY

Applicable servomotor

SJME-

@

01A

@

02A

@

04A

@

08A

@

B

as

ic

 s

pe

ci

fic

at

io

ns

Max. Applicable Motor capacity W

100

200

400

750

Continuous output current

Arms

0.84

1.1

2.0

3.7

Max. output current  

Arms

2.5

3.3

6.0

11.1

Input power supply

(Main circuit and control circuit) 

Voltage

Single-phase, 200 to 230 VAC, + 10 to -15%   (50/60 Hz)

Capacity KVA

0.40

0.75

1.2

2.2

Control Method

PWM control, sine wave current drive system

Feedback

Analogue incremental encoder (13 bits incremental equivalent)

Allowable load inertia

*1

kg

m

2

0.6 

×

 10

-4

3.0 

×

 10

-4

5.0 

×

 10

-4

10.0 

×

 10

-4

Usage / storage temperature

0 to +55° C / -20 to 70° C

Usage / storage humidity

90%RH or less (non-condensing)

Altitude

1000m or less above sea level

Vibration/shock Resistance

4.9m/s

2

 (0.5G) / 19.6m/s

2

(2G) 

Configuration

Base mounted 

Approx. mass

Kg

1.0

1.4

B

ui

lt-

in

 fu

nc

tio

ns

Dynamic brake (DB)

Operated at  main power OFF, servo alarm, servo OFF.(OFF after motor stops; ON when motor power is off.)

Regenerative processing

Optional (If the regenerated energy is too large, install a regenerative unit JUSP-RG08D)

Over-travel (OT) prevention function

P_OT, N_OT

Emergency stop

Emergency stop (E-STP)

LED display

4 LEDs (PWR, RDY, COM, ALM)

MECHATROLINK-II monitor

MECHATROLINK-II under communication : COM LED (Light ON)

Servo ON/OFF monitor

At Servo OFF : RDY LED (Light OFF), at Servo ON : RDY LED (Light Blinks)

Power supply status monitor 

Control / main-circuit power-supply OFF state: PWR LED (Light OFF) 

Control / main-circuit power-supply ON state: PWR LED (Light ON) 

Electronic gearing

0,01< A/B<100

Protection

Overcurrent, overvoltage, undervoltage, overload, main circuit sensor error, board temperature error, exces-

sive position error overflow, overspeed, encoder signal error, overrun protection, system error, parameter 

error

MECHATROLINK

Communication  

Comm. protocol 

MECHATROLINK-II

Transmission rate 

10 Mbps

Transmission cycle  1ms, 1.5ms, 2ms, 3ms, 4ms
Data length 

17 byte and 32 byte

Command input 

MECHATROLINK

communication

MECHATROLINK-II commands

(For sequence, motion, data setting/reference, monitor, adjustment, and other commands) 

Sequence Input signal 

Fixed input 

5 points   (fixed layout: external latch signal, zero return reduced speed signal, forward drive inhibiting signal, 

reverse run inhibiting signal, emergency stop signal)   

Sequence Output signal

Fixed output 

2 points   (fixed layout: servo alarm, brake interlock)   

AC  Servo Systems

8

Summary of Contents for JUNMA -

Page 1: ...Advanced Industrial Automation Compact size Tuning less concept MECHATROLINK II JUNMA SERVO SYSTEM Save s p a ce save w i r i n g save t i m e...

Page 2: ...30 of cabinet space and drastically reduces cabling and set up time A new concept in drive simplicity The Junma ML II series also shares other performance characteristics that have made Omron Yaskawa...

Page 3: ...st connect and run The advanced technology embodied in the Junma ML II series makes the dream of the no tuning servo solution a reality No gain parameters need to be set Just connect up to the motor a...

Page 4: ...lar interpolation as well as interrupt feeding The NCF and the Junma offer the ideal solution for applications where space is tight Full transparency from a remote host When the Junma is controlled by...

Page 5: ...CJ1 PLC series PLC open A global standard for industrial control programming PLCopen provides a standardized programming interface to harmonise the way people design and operate industrial control Sav...

Page 6: ...n Ratings 230 VAC Single phase 100 W to 750 W 2 39 Nm System Configuration Personal computer software CX One 200V SJDE 02 APA OY PULSE FIL REF AL1 AL2 AL3 C 0 8 9 A B D E F 4 5 32 6 7 1 C 0 8 9 A B D...

Page 7: ...0 5 0 10 0 Rated Power Rate kW s 16 0 12 3 26 7 38 1 Rated Angular Acceleration rad s2 50200 19300 21100 15900 Encoder Standard Analogue output encoder Allowable radial load 78 245 245 392 Allowable...

Page 8: ...C 20 to 70 C Usage storage humidity 90 RH or less non condensing Altitude 1000m or less above sea level Vibration shock Resistance 4 9m s2 0 5G 19 6m s2 2G Configuration Base mounted Approx mass Kg 1...

Page 9: ...energy is too large install a regenerative unit JUSP RG08D LED display 5 PWE REF AL1 AL2 AL3 Reference filter Select one of eight levels with FIL switch Protection Speed errors overload encoder errors...

Page 10: ...33 Units mm LA dia 4 LZ dia Cross Section A A 3 5 5 LC Encoder cable Servomotor main circuit cable Encoder connector 300 30 300 30 LL L LG LE 0 06 dia A LB dia S dia A 0 03 Motor connector 0 08 A A A...

Page 11: ...150 139 5 0 5 Mounting Pitch 5 5 5 Mounting Pitch 45 5 32 0 5 8 Model Cooling Fan SJDE 01ANA OY SJDE 02ANA OY SJDE 04ANA OY Not mounted Not mounted Mounted Approx mass 1kg Units in mm 180 75 5 19 16 1...

Page 12: ...0 140 5 130 0 5 14 17 4 5 5 5 33 75 Cooling fan 2 M4 mounting holes Mounting pitch Mounting Hole Diagram Visible outline 130 120 4 5 12 5 15 10 5 10 5 7 19 40 140 4 5 dia holes CN1 CN2 CNA CNB 200V SJ...

Page 13: ...AZ010S Power cable for Junma servomotors with brake SJME 0 AMB4C OY Flexible cables Standard Shielded Cable Bending radius Dynamic 10xDiameter Bending cycles 5 Million 1 5 m JZSP CHM030 01 5E 3 m JZSP...

Page 14: ...I Power cable Encoder cable Filter F G Symbol Name Model E Position Controller Unit for CJ1 PLC CJ1W NCF71 Position Controller Unit for CS1 PLC CS1W NCF71 Trajexia stand alone motion controller TJ1 MC...

Page 15: ...CQM1H PLB21 and CQM1 CPU43 V1 XW2B 20J6 3B 1 axis Use with CJ1M CPU21 22 23 XW2B 20J6 8A 1 axis XW2B 40J6 9A 2 axes F Cable to servo drive For the servo relay unit XW2B J6 B XW2B 20J6 8A XW2B 40J6 9A...

Page 16: ...gic controllers Human machine interfaces Remote I O Motion Drives Motion controllers Servo systems Inverters Control Components Temperature controllers Power supplies Timers Counters Programmable rela...

Reviews: