background image

Technical Guide for Limit Switches

Do not use the Switch in locations with corrosive gas, such as 
sulfuric gas (H

2

S or SO

2

), ammonium gas (NH

3

), nitric gas (HNO

3

),

or chlorine gas (Cl

2

), or high temperature and humidity. Otherwise, 

contact failure or corrosion damage may result.

If the Switch is used in locations with silicone gas, arc energy may 
create silicon dioxide (SiO

2

) on the contacts and a contact failure 

may result. If there is silicone oil, silicone sealant, or wire covered 
with silicone close to the Switch, attach a contact protective circuit 
to suppress the arcing of the Switch or eliminate the source of 
silicone gas generation.

Regular Inspection and Replacement

If the Switch is normally closed with low switching frequency (e.g., 
once or less than once a day), a reset failure may result due to the 
deterioration of the parts of the Switch. Regularly inspect the Switch 
and make sure that the Switch is in good working order.

In addition to the mechanical durability or electrical durability of the 
Switch described previously, the durability of the Switch may 
decrease due to the deterioration of each part, especially rubber, 
resin, and metal. Regularly inspect the Switch and replace any part 
that has deteriorated in order to prevent accidents from occurring.

If the Switch is not turned On or OFF for a long time, oxidation of 
the contacts may decrease contact reliability. Faulty continuity may 
result in accidents.

Be sure to mount the Switch securely in a clean location to ensure 
ease of inspection and replacement. The Switch with operation 
indicator is available, which is ideal if the location is dark or does 
not allow easy inspection or replacement.

Storage of Switch

When storing the Switch, make sure that the location is free of 
corrosive gas, such as H

2

S, SO

2

, NH

3

, HNO

3

, or Cl

2

, or dust and 

does not have a high temperature or humidity.

Be sure to inspect the Switch before use if it has been stored for 
three months or more.

Weather Resistance, Cold Resistance, and Heat 

Resistance

Silicon rubber is used to increase resistance to weather, cold, and 
heat. Silicon rubber, however, can generate silicon gas. (This can 
occur at room temperature, but the amount of silicon gas generated 
increases at higher temperatures.) Silicon gas will react as a result of 
arc energy and form silicon oxide (SiO

2

). If silicon oxide accumulates 

on the contacts, contact interference can occur and can interfere with 
the device. Before using a Switch, test it under actual application 
conditions (including the environment and operating frequency) to 
confirm that no problems will occur in actual.

Outdoor Use

If the Limit Switch is used in places with sludge or dust powder 
spray, make sure that the mechanical parts are sealed with a 
rubber cap.

The rubber materials exposed to ozone may deteriorate. Check 
that the rubber parts are made of environment-resistive materials, 
such as chloroprene, silicone, or fluorine rubber.

Due to capillary attraction, rainwater may enter the Limit Switch 
through the lead wires or sheath. Be sure to cover the wire 
connections in a terminal box so that they are not directly exposed 
to rainwater.

If the Limit Switch is used outdoors, the steel parts of the Limit 
Switch (such as the screws and plunger parts) may corrode.
Models with resistance against climatic conditions have been 
added to the series. Consider using outdoor models, such as the 
WL-

@

P1 or D4C-

@

P.

"Limit Switch is used outdoors" refers to an environment where the 
Limit Switch is exposed directly to rainwater or sunlight (e.g., 
multistory parking facilities) excluding locations with corrosive gas 
or salty breezes. A Limit Switch used outdoors may not release due 
to icing and may not satisfy specified standards.

Operation

Carefully determine the position and shape of the dog or cam so 
that the actuator will not abruptly snap back, thus causing shock. In 
order to operate the Limit Switch at a comparatively high speed, 
use a dog or cam that keeps the Limit Switch turned ON for a 
sufficient time so that the relay or valve will be sufficiently 
energized.

The method of operation, the shape of the cam or dog, the 
operating frequency, and the travel after operation have a large 
influence on the durability and operating accuracy of the Limit 
Switch. The cam or dog must be smooth in shape.

Appropriate force must be imposed on the actuator by the cam or 
dog in both rotary operation and linear operation.
If the dog touches the lever as shown below, the operating position 
will not be stable.

Easy to inspect

Difficult to inspect or install

The cover must be located in the 
direction ensuring ease of 
maintenance or inspection.

Incorrect

Correct

Snapped
back

Abruptly 
actuated

Incorrect

Correct

Snapped
back Abruptly 

actuated

Incorrect

Dog

Dog

Correct

http://www.ia.omron.com/

C-5

(c)Copyright OMRON Corporation 2007   All Rights Reserved. 

Summary of Contents for HL-5000 -

Page 1: ...terminal M5 tapping on the rear side conforming to various standards When placing an order add the code to the model number to indicate if ground terminal M5 tapping on the rear side is required G with ground terminal M5 tapping on the rear side Specifications Approved Standards Note Ask your OMRON representative for information on approved models Ratings Note 1 The above figures are for steady st...

Page 2: ...echanical 120 operations min Electrical 30 operations min Insulation resistance 100 MΩ min at 500 VDC Contact resistance 25 mΩ max initial value Dielectric strength 1 000 VAC 50 60 Hz for 1 min between terminals of the same polarity 1 500 VAC 50 60 Hz for 1 min between current carrying metal parts and ground 1 500 VAC 50 60 Hz for 1 min between each terminal and non current carrying metal part Rat...

Page 3: ...o 5 2 dia 0 2 0 mounting holes Roller Lever HL 5000 Adjustable up to 30R to 75R 4 1 60 6 21 4 65 7 0 8 60 3 0 8 51 3 0 8 15 5 Three M3 19 16 5 39 5 0 8 32 2 17 5 dia 6 6 1 M5 12 Allen head bolt M5 16 Allen head bolt 50 0 2 1 Resin roller 2 The head can be mounted in any of the four directions Adjustable Roller Lever HL 5030 4 1 60 6 21 4 62 8 0 8 53 4 0 8 15 5 145 max 19 16 5 2 3 dia 160 1 M5 12 A...

Page 4: ...minals are available 3 After inserting the solderless terminal into the Switch tighten the terminal screws securely 4 After wiring the Limit Switch insert the rubber connector into the groove of the box securely 5 Tighten the three mounting screws evenly The optimum tightening torque for each screw is 0 49 to 0 59 N m Applicable Lead Wires Note Do not use wires containing silicone otherwise a cont...

Page 5: ...tuator loosen the Allen head bolt on the side of the actuator lever Then the actuator can be set at any angle Head Direction Change HL 5000 HL 5030 HL 5050 HL5200 To change the head direction loosen the two mounting screws Then the head can be changed at 90 increments in one of four directions The head of the HL 5200 can be mounted in two directions only Refer to the following illustration 24 0 15...

Page 6: ... Switch or modify the Switch Doing so may result in insulation failures housing damage or physical injuries Be sure to evaluate the Switch under actual working conditions after installation Do not apply oil grease or other lubricants to the moving parts of the actuator otherwise the actuator may not operate correctly Furthermore intrusion of oil grease or other lubricants inside the Switch may red...

Page 7: ...actuator is constantly pressed it will fail quickly and reset faults may occur Inspect the Limit Switch periodically and replace it as required Mechanical Conditions for Switch Selection The actuator must be selected according to the operating method Refer to page 9 Check the operating speed and switching frequency 1 If the operating speed is extremely low the switching of the movable contact will...

Page 8: ...oblem at high DC voltages it may be more effective to connect a capacitor and resistor across the contacts rather than the load Performing testing to determine the most suitable method O O The operating time will be greater if the load is a re lay or solenoid Connecting the CR circuit in parallel to the load is effective when the power supply voltage is 24 or 48 V and in parallel to the contacts w...

Page 9: ...re selecting the model Be sure to install the Switch so that the Switch is free from dust or metal powder The actuator and the switch casing must be protected from the accumulation of dust or metal powder Do not use the Switch in locations where the Switch is exposed to hot water at a temperature greater than 60 C or steam Do not use the Switch under temperatures or other environmental conditions ...

Page 10: ...silicon oxide accumulates on the contacts contact interference can occur and can interfere with the device Before using a Switch test it under actual application conditions including the environment and operating frequency to confirm that no problems will occur in actual Outdoor Use If the Limit Switch is used in places with sludge or dust powder spray make sure that the mechanical parts are seale...

Page 11: ...racteristics of the actuator If a roller arm lever actuator is used do not attempt to actuate the Limit Switch in the direction shown below Do not modify the actuator to change the OP With the long actuator of an Adjustable Roller Lever Switch the following countermeasures against lever shaking are recommended 1 Make the rear edge of the dog smooth with an angle of 15 to 30 or make it in the shape...

Page 12: ...ever Lock Models Note Design the shape of the dog so that it does not come in contact with the other roller lever when the actuator is inverted Dog speed 0 5 m s max standard speed Dog speed 0 5 m s V 2 m s high speed θ φ V max m s y 45 45 0 5 0 5 to 0 8 TT 50 40 0 6 0 5 to 0 8 TT 60 to 55 30 to 35 1 3 0 5 to 0 7 TT 75 to 65 15 to 25 2 0 5 to 0 7 TT Dog speed 0 5 m s max Dog speed 0 5 m s min θ φ ...

Page 13: ...nufacturer of the system concerning maintenance and repairs Other The standard material for the switch seal is nitrile rubber NBR which has superior resistance to oil Depending on the type of oil or chemicals in the application environment however NBR may deteriorate e g swell or shrink Confirm performance in advance The correct Switch must be selected for the load to ensure contact reliability Re...

Page 14: ... may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations Systems...

Reviews: