H8BM
H8BM
11
PNP Output
INPUT COM
Count input 1
Count input 2
Count input 3
Count input 4
Count input 5
Count input 6
Count input 7
Count input 8
Count input 9
Count No.
selection
Reset input
I/O inhibit input
Re-monitor input
16 to 30 VDC
DISPLAY
Count value
Setting value
Count up
6 digit, 3-stage
preset Counter
x 9
Forecast output 1
Forecast output 2
Forecast output 3
Forecast output 4
Forecast output 5
Forecast output 6
Forecast output 7
Forecast output 8
Forecast output 9
Machine
stoppage output
RUN output
+24 V
0 V
24 VDC
+10%
–15%
5 V
Power
circuit
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
OUTPUT COM
Note:
H8BM-BD/-BDP outputs the forecast and machine stoppage values simultaneously.
OUTCOM
30 VDC
Max.
Load
All outputs
*
Connect a diode to suppress Counter surge when an inductive
load is connected.
Note:
When the load is short-circuited, the internal circuits may be
damaged.
Output
RUN, machine stoppage, forecast 1 to 9
Output method
Open collector
Applicable voltage
30 V max.
Rated current
100 mA
Residual voltage
2 V max.
Leakage current
100
µ
A max.
I/O Connections
39 V
Input Circuits
Output Circuits
5 V
Photocoupler
1.2 k
Ω
INCOM
Input
1.2 k
Ω
430
Ω
The input terminals are electrically
insulated from the internal circuits.
NPN Type
PNP Type
10
Ω
39 V
Output
OUTCOM*
The OUT COM and 0 V terminals
are internally connected.
OUTCOM
Output
10
Ω