H8BM

H8BM

10

 Connections

NPN Output

Count input 1

Count input 2

Count input 3

Count input 4

Count input 5

Count input 6

Count input 7

Count input 8

Count input 9

Count No.
selection

Reset input

I/O inhibit input

Re-monitor input

INPUT COM

16 to 30 VDC

DISPLAY

Count value
Setting value
Count up

6 digit, 3-stage
preset Counter
x 9

Forecast output 1

Forecast output 2

Forecast output 3

Forecast output 4

Forecast output 5

Forecast output 6

Forecast output 7

Forecast output 8

Forecast output 9

Machine
stoppage output

RUN output

OUTPUT COM

+24 V

0 V

24 VDC

+10%
–15%

5 V

Power
circuit

Load

Load

Load

Load

Load

Load

Load

Load

Load

Load

Load

Note:

Short-circuit terminals 1 and 7 when the power source of the Counter is shared. 
H8BM-BD/-BDP outputs the forecast and machine stoppage values simultaneously.

RUN, machine stoppage,
forecast outputs 1 to 9

30 VDC
Max.

Load

*

Connect a diode to suppress Counter surge when an inductive
load is connected.

Note:

When the load is short-circuited, the internal circuits may be
damaged.

Summary of Contents for H8BM Series

Page 1: ...C sensors RC Ordering Information Number of stages Output Model 3 stage setting NPN H8BM B 3 s age se g PNP H8BM BP 1 stage setting NPN H8BM BD s age se g PNP H8BD BDP Accessories Order Separately Rep...

Page 2: ...Note 1 Each channel operates on an separate I O 2 Pre forecast Displayed only on LCD No external output is provided Forecast Displayed on LCD and LED and output Output for each Counter Machine stoppa...

Page 3: ...ck generator LCD reference voltage generator Key switch circuits Input circuits count 1 to 9 reset re monitor output number request I O inhibit Count circuits One chip microcomputer LCD Output circuit...

Page 4: ...TER No Key Selects the Counter in sequence each time this Selector is pressed Any Counter whose forecast value is set to 0 is skipped in the RUN mode The following indicators light to show that the co...

Page 5: ...e Indication Forecast Value Setting Mode Indication Pre forecast Value Setting Mode Indication Flashing Machine Stoppage Value Setting Mode Indication Flashing Note 1 The modes marked are not provided...

Page 6: ...is time the count value is only displayed and not recovered internally The Counter whose count value is displayed remains in the RUN mode 2 Press the COUNTER No Key or apply the Counter No select inpu...

Page 7: ...e of only the Counter whose count value is cur rently displayed is reset in RUN mode only 9 Clearing Settings The count values of all the Counters can be cleared by simultaneously holding down the RES...

Page 8: ...ime value Pre forecast indicator Forecast output and indicator Machine stoppage output and indicator Totalizing Counter Operation Reset input Count input 999999 0 Count value Forecast output indicator...

Page 9: ...en mounting it to en sure a proper working space Other components Terminal Arrangement 22 23 24 25 26 27 28 Reset input Count No selection Count input 1 Count input 2 Count input 3 Count input 4 Count...

Page 10: ...recast output 5 Forecast output 6 Forecast output 7 Forecast output 8 Forecast output 9 Machine stoppage output RUN output OUTPUT COM 24 V 0 V 24 VDC 10 15 5 V Power circuit Load Load Load Load Load L...

Page 11: ...d Load Load Load Load Load Load Load OUTPUT COM Note H8BM BD BDP outputs the forecast and machine stoppage values simultaneously OUTCOM 30 VDC Max Load All outputs Connect a diode to suppress Counter...

Page 12: ...1 High level transistor ON Min switching capacity 5 mA max Residual voltage 4 V max 2 Low level transistor OFF Leakage current 1 5 mA max 3 Power voltage range 20 4 to 30 VDC Use of the OMRON TL XD o...

Page 13: ...nner as well as strong acids or strong alkalies can damage the housing of the Counter Others To conduct a dielectric strength test between the electric circuits and non current carrying metal parts wi...