H7BR
H7BR
17
Mode
Setting item
Applicable model
Description
Setting procedure
H7BR-B
H7BR-C
Run
Set value 1,
Yes
Yes
Compared to the present
Sequence when changing a digit using the increment
mode
2
value. Determines the
keys (1 to 6).
timing of the control out-
put according to the out-
put mode. The DISPLAY
key switches between
The +/- key changes the set value mark. (H7BR-C
set value 1 and 2. (Double
only.)
preset model only.)
Batch count
Yes
No
Turns ON the batch out-
Sequence when changing a digit using the
set value
put when the preset
increment keys (1 to 6).
number of cycles have
been completed.
Set
Input mode
Yes
Yes
Determines the input mode Press keys 1 to 6 to change the displayed mode.
mode
selecting from UP, DOWN
and REVERSIBLE modes.
*H7BR-B only.
Output mode Yes
Yes
Determines the control
Press keys 1 to 6 to change the displayed mode.
output type. (Refer to
H7BR-B
the
Standard Counter
Output Operations and
Reve/- Range
Counter Output Operation
H7BR-C
sections.) Determines
Double preset model only.
the output time for control
output (Output 2).
Press keys 1 to 6 to change the Output 2 time.
(Applicable to output modes C, R, K, P, Q and A
only.)
Output time 1 Yes
Yes
Determines the output
Press keys 1 to 6 to change the displayed mode.
(double
time of the control out-
preset model
put (OUT 1) for double
only)
preset model counters.
*H7BR-BW only.
Applicable to output modes C, R, K, P, Q and A only.
CP1, CP2
Yes
Yes
Switches the count input
Press keys 1 to 6 to change the displayed mode.
count speed
filter to protect against
errant counts due to
interference.
The counting speed of CP1 or CP2, whichever is
faster, is set by the response speed of the gate
and compensation inputs, when the input mode
is set to REVERSIBLE C, make the counting
speeds of CP1 and CP2 equal.
Min. reset
Yes
Yes
Determines the initial
Press keys 1 to 6 to change the displayed mode.
time
signal width of the
external reset.
Decimal
Yes
Yes
Determines the decimal
Move the decimal point position from left to right
point
point position of the
with keys 1 to 6.
present and set values.
Prescale
Yes
Yes
Can calculate and display
Change the value of the digits with the correspond-
value
a physical parameter
ing keys, 1 to 5.
(volume, length, etc.)
from the present value.
For example, if one count
input represented a
movement of 0.02 mm,
the prescale value
would be 0.02.
Values from 0.001 to
99.999 are possible.
■
SETTING ITEM TABLE