H3CR-G
H3CR-G
30
Accessories (Order Separately)
Name/specifications
Models
Flush Mounting Adapter
Y92F-30
g
p
Y92F-70
Y92F-71
Mounting Track
50 cm (
l
) x 7.3 mm (t)
PFP-50N
1 m (
l
) x 7.3 mm (t)
PFP-100N
1 m (
l
) x 16 mm (t)
PFP-100N2
End Plate
PFP-M
Spacer
PFP-S
Protective Cover
Y92A-48B
Track Mounting/
F
t C
ti
S
k t
8-pin
P2CF-08
g
Front Connecting Socket
8-pin, finger safe type
P2CF-08-E
Back Connecting Socket
8-pin
P3G-08
g
8-pin, finger safe type
P3G-08 with Y92A-48G (see note 1)
Time Setting Ring
Setting a specific time
Y92S-27
Limiting the setting range
Y92S-28
Panel Cover (see note 2)
Light gray (5Y7/1)
Y92P-48GL
Black (N1.5)
Y92P-48GB
Medium gray (5Y5/1)
Y92P-48GM
Hold-down Clip (see note 3)
For PL08 and PL11 Sockets
Y92H-1
For PF085A Socket
Y92H-2
Note:
1. Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 Socket.
2. The Time Setting Ring and Panel Cover are sold together.
3. Hold-down Clips are sold in sets of two.
Specifications
General
Item
H3CR-G8L
H3CR-G8EL
Functions
Star-delta timer
Star-delta timer with instantaneous output
Pin type
8-pin
Operating/Reset method
Time-limit operation/Self-reset
Output type
Time-limit: SPST-NO (star operation circuit)
SPST-NO (delta operation circuit)
Time-limit:
SPST-NO (star operation circuit)
SPST-NO (delta operation circuit)
Instantaneous: SPST-NO
Mounting method
DIN track mounting, surface mounting, and flush mounting
Approved standards
UL508, CSA C22.2 No.14, NK, Lloyds
Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2.
Output category according to EN60947-5-1.
Time Ranges
Time unit
Star operation time ranges
Full scale setting
6
0.5 to 6 s
g
12
1 to 12 s
60
5 to 60 s
120
10 to 120 s
Star-delta transfer time
Programmable at 0.05 s, 0.1 s, 0.25 s or 0.5 s
electronic components distributor