background image

6

24-hour/Weekly Time Switch 

H2F

Precautions

Flush Mounting

1. To mount the adapter to the panel cutout, first deform the adapter

by pushing it on the two opposing corners (as indicated by arrows
A. Then push part B into the cutout (i.e., toward the back of the
panel).

2. After the adapter is mounted, insert the H2F as shown in the fig-

ure below. Secure the H2F by tightening the two mounting screws
(M3 x 16) included as accessories.

3. If the lead wires have been connected to the H2F from the front of

the panel before the H2F is mounted in the panel, engage the
H2F to part A of the adapter and push it in the direction of B. Then
tighten the two screws as described in 2.

Time Setting

To set the time, turn the center knob clockwise to the correct time.
Turning it counterclockwise or turning it with your fingers hooked on
the setting bracket may cause a malfunction.

With 24-hour models, set the hour to the arrow on the upper left cor-
ner of the front panel and the minute to the arrow on the center knob.

With 1-week models, set the day of the week to the arrow on the
upper left corner of the front panel and the hour to the arrow on the
center knob.

Use the gold setting tabs to set the ON time and the silver ones to set
the OFF time. Position the thick leg of the tab toward the outside of
the dial and insert the tab securely into the groove on the dial.

Three pairs of setting tabs are attached.
Store the spare tabs in the compartment at the lower right corner of
the front panel.

Panel

Adapter

B

A

Panel

Lead wire

B

A

H2F Time Switch

Summary of Contents for H2F -

Page 1: ...ntrol outputs Minute dial assures accurate settings Models with memory protection available Control outputs can be manually turned ON OFF Designed for surface flush or track mounting Model Number Structure Model Number Legend 1 Operation cycle D 24 hour W 1 week 2 Motor type None Synchronous motor M Quartz motor 3 Mounting method None Flush mounting F Surface mounting DIN track mounting 4 Output t...

Page 2: ...tz motor with memory protection Flush SPST NO H2F D H2F DM H2F WM SPDT H2F DC H2F DMC H2F WMC Surface track SPST NO H2F DF H2F DMF H2F WMF SPDT H2F DFC H2F DMFC H2F WMFC Extra Programming Tabs 1 pair for each ON OFF See note 1 Y92S 21 Rechargeable Battery See note 2 Y92S 42 Operation period Minimum division Minimum set time Maximum set time 24 hour 15 min 15 min 23 h 45 min 1 week 1 h 2 h 166 h Op...

Page 3: ...ax Memory protection against power failure 180 h min See note 3 Insulation resistance 100 MΩ min at 500 VDC Dielectric strength 2 000 VAC 50 60 Hz for 1 min between current carrying terminals and non current carrying metal parts 1 000 VAC 50 60 Hz for 1 min between non continuous contacts Vibration resistance Destruction 16 7 Hz 2 mm single amplitude Malfunction 10 to 55 Hz 0 25 mm single amplitud...

Page 4: ...to the load 2 Do not exceed the following torque when tightening the screws Specified torque 0 8 N m Maximum torque 0 98 N m 3 When connecting leads to the terminal block use the same wire size for all leads If different wire sizes are used the thinner leads may come off during operation 4 Recommended lead wires AWG18 to AWG24 cross section 0 205 to 0 823 mm2 solid or twisted wire 5 When using cri...

Page 5: ...ated Mounting Dimensions Surface Mounting H2F DF DMF WMF Track Mounting H2F DFC DMFC WMFC Mounting Holes M3 5 6 29 Two M3 holes Screw size M3 x 45 included Flush Mounting H2F D DM WM DC DMC WMC Panel Cutout Recommended panel thickness 1 to 3 2 mm Note The mounting adapter and screws are included 65 5 ...

Page 6: ...Time Setting To set the time turn the center knob clockwise to the correct time Turning it counterclockwise or turning it with your fingers hooked on the setting bracket may cause a malfunction With 24 hour models set the hour to the arrow on the upper left cor ner of the front panel and the minute to the arrow on the center knob With 1 week models set the day of the week to the arrow on the upper...

Page 7: ...F Be sure to load the Battery before using the H2F If the Battery is not loaded the H2F will not work properly Be sure to load the Battery with the correct polarity The polarity is indicated in the battery box After loading the Battery be sure to place the cover on the battery box The Battery is fully charged before shipment The Battery may lose its charge while the Battery is stored Therefore the...

Page 8: ...of the terminals or the back panel while power is being supplied Doing so may result in electric shock Be sure to mount the terminal cover after wiring Before changing times or other settings while power is being supplied either turn OFF the power on the load side or set the output ON OFF switch to OFF and confirm the safety of the system Unexpected operation may occasionally result Tighten the te...