background image

2

Motor Timer 

H2C

Accessories (Order Separately)

Note: 1.

Supplied with H2C-S/-SR models.

2.

Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 or P3GA-11 Socket.

3.

Hold-down Clips are sold in sets of two.

Specifications

Time Ranges

Five time ranges are available for each timer by turning the time range selector every 60 degrees.

Note:

Rated time is displayed on the window.

Ratings

Note:

The front panel of the timer is color coded to identify the following supply voltage classifications:
100 to 120 V: Blue
200 to 240 V: Red
Other classes: Black

Name/specifications

Models

Flush Mounting Adapter

Y92F-30

Time Setting Ring (See note 1.)

Y92A-Y1

Mounting Track

50 cm (l) 

´

 7.3 mm (t)

PFP-50N

1 m (l) 

´

 7.3 mm (t)

PFP-100N

1 m (l) 

´

 16 mm (t)

PFP-100N2

End Plate

PFP-M

Spacer

PFP-S

Protective Cover

Y92A-48B

Track Mounting/Front Connecting 
Socket

8-pin

P2CF-08

8-pin, finger safe type

P2CF-08-E

11-pin

P2CF-11

11-pin, finger safe type

P2CF-11-E

Back Connecting Socket

8-pin, screw terminal

P3G-08

8-pin, finger safe type

P3G-08 with Y92A-48G (See note 2.)

11-pin

P3GA-11

11-pin, finger safe type

P3GA-11 with Y92A-48G (See note 2.)

Hold-down Clip (See note 3.)

For PL08 and PL11 Sockets

Y92H-1

For PF085A Socket

Y92H-2

Time range code

Position of time range selector

A

1.25 to 30 s

7.5 s to 3 min

1.25 to 30 min

7.5 min to 3 h

1.25 to 30 h

B

0.2 to 6 s

2 to 60 s

0.2 to 6 min

2 to 60 min

0.2 to 6 h

C

0.5 to 12 s

5 to 120 s

0.5 to 12 min

5 to 120 min

0.5 to 12 h

Item

H2C

Rated supply voltage (motor and 
clutch)

24, 48, 100, 110, 115, 120, 200, 220, or 240 VAC (50/60 Hz) (see note)

Operating voltage range

85% to 110% of rated supply voltage

Power consumption

4.2 VA max. (3.96 W max.)

Reset voltage

10% max. of rated supply voltage

Reset time

Minimum power-opening time: 0.5 s
Minimum pulse width:

0.5 s

Control outputs

6 A at 250 VAC, resistive load (cos

φ

 = 1)

Mounting method

Flush mounting (except for H2C-F/-FR models), surface mounting, DIN track mounting

Summary of Contents for H2C

Page 1: ... Number Structure Model Number Legend 1 External Connection Attachment None 11 pin socket S 11 pin socket time setting ring 8 8 pin socket F Front screw 2 Operation Resetting System None Time limit operation self resetting R Time limit operation electric resetting Ordering Information List of Models 1 2 H2C Operation resetting system Internal connection Terminal Time limit contact Instantaneous co...

Page 2: ...pin finger safe type P2CF 08 E 11 pin P2CF 11 11 pin finger safe type P2CF 11 E Back Connecting Socket 8 pin screw terminal P3G 08 8 pin finger safe type P3G 08 with Y92A 48G See note 2 11 pin P3GA 11 11 pin finger safe type P3GA 11 with Y92A 48G See note 2 Hold down Clip See note 3 For PL08 and PL11 Sockets Y92H 1 For PF085A Socket Y92H 2 Time range code Position of time range selector A 1 25 to ...

Page 3: ...ons min under no load at 1 800 operations h Electrical 500 000 operations min 3 A at 250 VAC resistive load at 1 800 operations h See Life test Curve for other details Motor life expectancy 20 000 h Approved standards UL917 CSA C22 2 No 14 Conforms to EN61812 1 and IEC60664 1 4 kV 1 except for H2C F models Output category according to EN60947 5 1 except for H2C F models EMC except for H2C F models...

Page 4: ... are for when the clutch is in the excited reset state H2C 8 H2C F H2C S H2C F R H2C SR H2C 8R B2 B1 22 24 A2 21 15 A1 18 16 B2 B1 22 24 A2 21 15 A1 18 16 6 7 8 9 10 11 1 2 3 4 5 B2 B1 22 24 A2 21 15 A1 18 16 6 7 8 9 10 11 1 2 3 4 5 Clutch coil DIN 46 199 5 Clutch coil DIN 46 199 5 ...

Page 5: ...stantaneous contacts NC 11 21 8 22 Instantaneous contacts NO 11 21 9 24 Timing operation indicator lamp OFF at time up See note Instantaneous contacts NC 11 21 8 22 Instantaneous contacts NO 11 21 9 24 Timing operation indicator lamp OFF at time up See note Power failure time t Rt Resetting time Time limit contacts NC 8 5 Time limit contacts NO 8 6 Time limit contacts NC 1 15 4 16 Time limit conta...

Page 6: ...current of 1 A max dimension L becomes 10 mm min with an interval of 0 mm between timers For a load current of 3 A max dimension L becomes 15 mm min with an interval of 5 mm between timers For a load current of 6 A max dimension L becomes 20 mm min with an interval of 10 mm between timers Two M4 or 4 5 dia holes 37 dia 100 8 103 1 80 16 3 16 3 85 7 81 5 92 2 H2C 8 H2C 8R These dimensions vary with...

Page 7: ... 40 0 2 40 0 2 7 8 4 35 4 20 3 19 3 1 3 5 4 5 70 max 50 max 20 3 max P2CF 08 E Finger Safe Terminal Type Conforming to VDE0106 P100 Surface Mounting Holes Two 4 5 dia or two M4 50 max 70 max 21 5 max P2CF 08 Eight M3 5 x 7 5 sems Two 4 5 dia holes Terminal Arrangement Internal Connections Top View Two 4 5 dia holes Eight M3 5 x 7 5 sems ...

Page 8: ... 2 max P2CF 11 Eleven M3 5 x 7 5 sems Terminal Arrangement Internal Connections Top View Two 4 5 dia holes Two 4 5 dia holes Eleven M3 5 x 7 5 sems 45 45 4 9 17 45 45 25 6 4 5 16 3 6 2 34 47 7 x 47 7 48 x 48 47 4 16 5 24 6 27 6 27 dia P3GA 11 27 dia Finger Safe Terminal Cover Conforming to VDE0106 P100 Y92A 48G Twelve 6 4 dia holes P3G 08 Terminal Arrangement Internal Connections Bottom View Termi...

Page 9: ...Plate PFP M M4 x 8 pan head screw Spacer PFP S Y92A Y1 Y92A 48B Time Setting Ring Protective Cover The time setting ring locks the time setting knob to store the set time to facilitate its resetting A maximum of two time setting rings are connectable per timer The protective cover shields the front panel particular ly the time setting section from dust dirt and water as well as prevents the set va...

Page 10: ...ain voltage fluctuations in the power supply within the specified range Use a switch relay or other contact so that the rated power supply voltage will be reached within 0 1 s If the power supply voltage is not reached quickly enough the H2C may malfunction or outputs may be unstable Leaving the H2C with outputs ON at a high temperature for a long time may hasten the degradation of internal parts ...

Page 11: ...t for H2C F as a built in timer conforms to EN61812 1 provided that the following conditions are satisfied Handling Before dismounting the H2C from the Socket make sure that no voltage is imposed on any terminal of the H2C Applicable Sockets P2CF P2CF E PF085A PL Wiring Basic insulation is ensured between the motor circuit clutch circuit and control output circuit However the H2C 8 motor circuit a...

Page 12: ...hall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s application or use of the products Take all necessary steps to determine the suitability of the product for the systems machines and equipment with which it will be used Know and observe all prohibitions of use applicable to this product NEVER USE THE PRODUCTS ...