Compact Non-Contact Door Switch/Flexible Safety Unit

D40A/G9SX-NS

Electronic Detection Mechanism for 
Better Stability in Non-contact Door 
Switch Operation

Features

Be sure to read the 

“Safety Precautions” 

on page 24 and 

the 

“Precautions for All Safety Door Switches”

.

 Easy-to-see 2-Color Indicators 

Switch status is easy to see at a glance with 
these red/yellow LED indicators. 

Red:  

Open door  

detected. 

Yellow: 

Closed door 

detected. 

Not lit: 

Power OFF 

or failure 

 

Small Actuator 

An actuator that is smaller than the switch 
saves space, even inside the door.  
Even when mounted with an L-bracket, the 
actuator's height will not hinder installation or 
operation. 

 Connect Up to 30 Switches to a Single Controller 

Up to 30 Switches

Reduce costs by connecting up to 30 Switches to a single Controller.  

 Mount from Either Side 

Compact

Switch

Actuator

Swinging doors

Swinging doors

Sliding doors

Sliding doors

Mount from whichever side provides the 
easiest wiring path to enable mounting to all 
types of doors.

Summary of Contents for G9SX-NS

Page 1: ...pen door detected Yellow Closed door detected Not lit Power OFF or failure Small Actuator An actuator that is smaller than the switch saves space even inside the door Even when mounted with an L bracket the actuator s height will not hinder installation or operation Connect Up to 30 Switches to a Single Controller Up to 30 Switches Reduce costs by connecting up to 30 Switches to a single Controlle...

Page 2: ...ty Note The figure is intended only as an illustration Stable Detection with the D40A s New System Slow Detects slow lateral operation Error Error It is nearly impossible to tell which door is open in a multi door application Issue 2 If an error occurs It s impossible to tell if there is a door open or if an error has occurred The system cannot be started because the Controller has turned OFF the ...

Page 3: ...Two OFF delay safety outputs Logical AND connection input Logical AND connection output Logical AND connection input Expansion Units to Easily Increase the Number of Outputs with the G9SX NSA Mechanical Safety Door Switches Can Also Be Connected with the G9SX NSA Indicators That Make Maintenance Easier Up to 25 Outputs G9SX EX Expansion Unit Logical AND connection error Safety Door Switches D40A T...

Page 4: ...G9SA D40A G9SX NSA Emergency stop switch Two Controllers D40B One Controller Solution 1 Solution 2 Another Controller has to be added to use an OFF delay timer Issue 2 The G9SA must be added to use an OFF delay timer G9SA Wiring OFF delay output G9SA 321 T D40B J1 Emergency stop switch D40A Emergency stop switch G9SX BC G9SX NSA Three Controllers Two Controllers The D40A Simplifies the Configurati...

Page 5: ...ller EX Expansion Unit 2 Output Configuration Instantaneous Safety Outputs 2 2 outputs 4 4 outputs 3 Output Configuration OFF delayed Safety Outputs 0 None 2 2 outputs 4 Output Configuration Auxiliary Outputs 1 1 output 2 2 outputs 5 Max OFF delay Time D40A Controller T03 3 s Variable Expansion Unit Blank No OFF delay T OFF delay 6 Terminal Block Type RT Screw terminals RC Spring cage terminals Cl...

Page 6: ...n Ranges on page 11 Influence of temperature max 20 of operating distance at 23 C within temperature range of 10 to 55 C Ambient operating temperature 10 to 55 C no icing or condensation Ambient operating humidity 25 to 85 Insulation resistance between charged parts and case 50 MΩ max at 500 VDC Dielectric strength between charged parts and case 1 000 VAC for 1 min Vibration resistance 10 to 55 to...

Page 7: ...red when Units are mounted side by side G9SX NS202 G9SX NSA222 T03 0 4 A max load current Expansion Unit Item Model G9SX NS202 G9SX NSA222 T03 G9SX EX Rated supply voltage 24 V DC Operating voltage range 15 to 10 of rated supply voltage Rated power consumption 3 W max 4 W max 2 W max Item Model G9SX NS202 G9SX NSA222 T03 Safety input 1 Operating voltage 20 4 VDC to 26 4 VDC internal impedance appr...

Page 8: ...ms max Non contact Door Switch input OFF 6 10 ms max 4 ON state residual voltage 3 0 V max safety output auxiliary output OFF state leakage current 0 1 mA max safety output auxiliary output Maximum wiring length of safety input logical AND connection input and Non contact Door Switch input 100 m max External connection impedance 100 Ω max and 10 nF max Reset input time Reset button pressing time 1...

Page 9: ...its and G9SX BC Basic Units In this configuration each Controller or Advanced Unit can have up to five Expansion Units Item Model G9SX NS202 G9SX NSA222 T03 G9SX EX Number of Units connected per logical AND output 4 Units max Total number of Units connected by logical AND 1 20 Units max Number of Units connected in series by logical AND 5 Units max Max number of Expansion Units connected 2 5 Units...

Page 10: ...15 ms 100 ms 1 The maximum response time is the time it takes the output to switch from ON to OFF after the input switches from ON to OFF 2 The maximum operating time is the time it takes the output to switch from OFF to ON after the input switches from OFF to ON Max response time excluding Expansion Units 1 Max operating time excluding Expansion Units 2 Non contact Door Switch input 20 ms 100 ms ...

Page 11: ...14 to S54 are internally redundant Internal Circuit Diagram D40A 1C X Y Sensing surface Target marks 16 14 12 10 8 6 4 2 0 6 4 2 0 2 4 6 Distance from the target mark on the switch X mm Operating distance Y mm ON OFF 0 2 4 6 8 10 12 14 15 10 5 0 5 10 15 Distance from the target mark on the switch Z mm Operating distance Y mm ON OFF Z Y Sensing surface Target marks 3 2 Logical AND input Safety outp...

Page 12: ...T32 T31 A1 X1 D2 D1 Note 1 Above outline drawing is for models with spring cage terminals RC 2 For models with spring cage terminals RC only Typical dimension Terminal arrangement Non contact Door Switch Controller G9SX NS202 No OFF DELAY L1 S54 S44 S24 S14 D4 A2 T42 T41 T22 T21 A1 X2 X1 Y1 T12 T11 T33 T31 T1 ERR EI AND FB ED T2 PWR T32 D2 D3 D1 G9SX NSA222 T03 24VDC NS 0 5 0 4 0 3 0 2 3 0 2 5 2 0...

Page 13: ... G9SX EX041 T 43 33 23 13 PWR 44 A2 14 24 A1 34 X2 EI ERR 43 33 23 13 PWR 44 A2 14 24 A1 34 X2 ED ERR G9SX EX041 T Expansion Unit with OFF Delay G9SX EX401 Expansion Unit Terminal arrangement Note 1 Above outline drawing is for models with spring cage terminals RC 2 For models with spring cage terminals RC only Typical dimension ...

Page 14: ...White White Black Black Black Brown Brown Brown Blue Blue Blue Signal name Wire color Description of operation Non contact Door Switch power supply input Brown Supplies power to the D40A Connect to the D3 and D4 terminal of the G9SX NS Blue Non contact Door Switch input White Inputs signals from the G9SX NS The Non contact Door Switch input must be ON as a required condition for the Non contact Do...

Page 15: ...f the safety output of Unit B is AND An AND of inputs a and b is output To set the safety outputs of the subsequent Unit in the ON state its logical AND connection preset switch must be set to AND enable and the high signal must be input to T41 of the subsequent unit Instantaneous safety output S14 S24 Turns ON OFF according to the state of the safety inputs Non contact Door Switch inputs feedback...

Page 16: ...t Unit in the ON state its logical AND connection preset switch must be set to AND enable and the high signal must be input to T41 of the subsequent unit Cross fault detection input Y1 Selects the mode for the failure detecting cross fault detecting function for the safety inputs of G9SX corresponding to the connection of the cross fault detection input Keep Y1 open when using T11 T21 Cross fault ...

Page 17: ...ND enabled A manual reset is required when an emergency stop is used Connecting Expansion Units The G9SX EX and G9SX EX T Expansion Units can be connected to a G9SX NSA222 T3 Non contact Door Switch Controller to increase the number of safety outputs They cannot be connected to a G9SX NS202 A maximum of five Expansion Units can be connected to one G9SX NSA222 T03 This may be a combination of G9SX ...

Page 18: ...switch is set to OFF Note A setting error will occur and Unit B will lock out if the logical AND setting switch on the Unit B is set to OFF 4 Setting the OFF delay Time G9SX NSA222 T03 The OFF delay preset time on G9SX NSA222 T03 is set from the OFF delay time preset switch 1 each on the front and back of the Unit Normal operation will only occur if both switches are identically set An error will ...

Page 19: ... cases With automatic reset while a high signal is input to T33 With manual reset while a high signal is input to T32 Flashes when an error relating to feedback reset input occurs AND Orange Logical AND input indicator Lights while a high signal is input to T41 Flashes when an error relating to logical AND connection input occurs EI Orange Instantaneous safety output indicator Lights while the Ins...

Page 20: ...o the D40A 3 Replace with a new product 4 Replace with a new D40A FB flashes Fault involved with feedback reset inputs 1 Error in the wiring of feedback reset input 2 Failure of the circuit of feedback reset input 1 Check the wiring to T31 T32 and T33 2 Replace with a new product Fault in Expansion Unit 1 Improper feedback signals from Expansion Unit 2 Abnormal supply voltage to Expansion Unit 3 F...

Page 21: ...D connection preset switch 3 Replace with a new product All indicators except PWR flash Supply voltage outside the rated value 1 Supply voltage outside the rated value 1 Check the supply voltage to the Units ERR indicator Other indicators Fault Expected cause of the fault Check points and measures to take Off T1 flash Mismatch between input 1 and input 2 The input status between input 1 and input ...

Page 22: ...top Switch S2 Non contact Door Switch S3 Reset Switch KM1 KM2 Contactor M1 3 phase motor Note 1 This example corresponds to category 2 2 For details on Non contact Door Switch wiring refer to pages 15 and 16 or to the User s Manual open 23 24 11 12 S2 S1 OFF AND NC G9SX NSA222 T03 Control circuit KM2 KM1 NC NC Black Brown White Blue S3 24 V S14 M1 KM2 KM1 Motor controller 24 V GND Feedback Loop Mo...

Page 23: ...ircuit G9SX BC202 Unit 1 Control circuit Black Brown White Blue S3 KM4 KM3 S14 S24 A2 KM2 KM1 S14 S24 A2 A1 T11 T11 T12 T21 T22 T31 T32 T33 Y1 L1 L2 X1 X2 A1 D1 D3 D4 T31 T32 T33 T41 T42 D2 L1 X1 X2 Non contact Door Switch Actuator Feedback Loop Feedback Loop Unit 2 S14 S24 Unit 1 S14 S24 G9SX BC202 Unit 1 G9SX NS202 Unit 2 Reset switch S2 KM1 KM2 N C contact KM1 KM2 N O contact Logical AND output...

Page 24: ...nctions or damages to the product 14 Auxiliary error outputs and auxiliary monitoring outputs are NOT safety outputs Do not use these outputs as safety outputs Such incorrect use will cause loss of safety functions of the G9SX and its relevant system Also logical AND connection outputs can only be used for logical AND connections with the G9SX 15 After installing the G9SX NS qualified personnel mu...

Page 25: ...er the following conditions 1 In direct sunlight 2 At ambient temperatures not between 10 and 55 C 3 At relative humidity not between 25 and 85 or under temperature changes that could causes condensation 4 In corrosive or combustible gases 5 Where subject to vibration or mechanical shock beyond the rated values 6 Where subject to contact with water oil or chemicals 7 In an atmosphere containing ex...

Page 26: ... Screw Terminals Use the following to wire the G9SX NS RT Tighten each screw to the specified torque of 0 5 to 0 6 N m or the G9SX NS may malfunction or generate heat Strip the wire for no longer than 7 mm 2 G9SX NS RC with Spring cage Terminals Use the following to wire the G9SX NS RC 3 Logical AND Connections Use VCTF cables or shielded cables for logical AND connect ions between Units 20 Connec...

Page 27: ...ng AC and DC circuits connect at least two G9SX EX Units and use them respectively as dedicated DC circuit and AC circuit contact outputs 30 Safety Application Controller s Relay durability depends greatly on the switching condition Confirm the actual conditions of operation in which the Relay will be used in order to make sure the permissible number of switching operations When the accumulated nu...

Page 28: ...e products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations Systems machines and equipment...