background image

G7SA

G7SA

133

Specifications

 Ratings

Coil

Rated

voltage

Rated current

Coil resistance

Must-operate

voltage

Must-release

voltage

Max.

voltage

Power consumption

24 VDC

4 poles: 15 mA
6 poles: 20.8 mA

4 poles: 1,600 

6 poles: 1,152 

75% max. (V)

10% min. (V)

110% (V)

4 poles: Approx. 360 mW
6 poles: Approx. 500 mW

Note:

1. The rated current and coil resistance are measured at a coil temperature of 23

°

C with tolerances of 

±

15%.

2. Performance characteristics are based on a coil temperature of 23

°

C.

3. The value given for the maximum voltage is for voltages applied instantaneously to the Relay coil (at an ambient temperature of

23

°

C) and not continuously.

Contacts

Load

Resistive load (cos 

φ

 =1)

Rated load

6 A at 250 VAC, 6 A at 30 VDC

Rated carry current

6 A

Max. switching voltage

250 VAC, 125 VDC

Max. switching current

6 A

Max. switching capacity (reference value)

1,500 VA, 180 W

 Characteristics

Safety Relay Sockets

Model

Continuous current

Dielectric strength

Insulation resistance

P7SA-14

j

6 A (see note 1)

2,500 VAC for 1 min. between poles

100 M

 min. (see note 2)

Note:

1. If the P7SA-1

j

F is used between 55 and 85

°

C, reduce the continuous current (from 6A) by 0.1 A for every degree.

2. Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC.

3. When using the P7SA-1

j

F-ND at 24 VDC, use at an ambient operating temperature from –25 to 55

°

C.

Safety Relays

Contact resistance

100 m

 max. (The contact resistance was measured with 1 A at 5 VDC using the

voltage-drop method.)

Operating time (see note 2)

20 ms max.

Response time (see note 2)

10 ms max. (The response time is the time it takes for the normally open contacts to open
after the coil voltage is turned OFF.)

Release time (see note 2)

20 ms max.

Maximum operating
f

Mechanical

36,000 operations/hr

a

u

ope a

g

frequency

Rated load

1,800 operations/hr

Insulation resistance

100 M

 min. (at 500 VDC)

(The insulation resistance was measured with a 500-VDC megger at the same places that the
dielectric strength was measured.)

Dielectric strength (see notes 3, 4)

Between coil contacts/different poles: 4,000 VAC, 50/60 Hz for 1 min
(2,500 VAC between poles 3–4 in 4-pole Relays or poles 3–5, 4–6, and 5–6 in 6-pole Relays.)

Between contacts of same polarity: 1,500 VAC, 50/60 Hz for 1 min

Vibration resistance

10 to 55 Hz, 1.5-mm double amplitude

Shock resistance

Destruction

1,000 m/s

2

S oc

es s a ce

Malfunction

100 m/s

2

Life expectancy

Mechanical

10,000,000 operations min. (at approx. 36,000 operations/hr)

e e pec a cy

Electrical

100,000 operations min. (at the rated load and approx. 1,800 operations/hr)

Min. permissible load (see note 5)
(reference value)

5 VDC, 1 mA

Ambient temperature (see note 6)

Operating: –40

°

C to 85

°

C (with no icing or condensation)

Storage:

–40

°

C to 85

°

C (with no icing or condensation)

Ambient humidity

Operating: 35% to 85%
Storage:

35% to 85%

Weight

4 poles: Approx. 22 g
6 poles: Approx. 25 g

Approved standards

EN61810-1 (IEC61810-1), EN50205, UL508, CSA22.2 No. 14

Note:

1. The values listed above are initial values.