Slim Relay

 G3RV

1

Slim Relay

G3RV

The World's First Industrial Slim Relay

• G2RV compatible 

• LED indicator built in SSR

• Push-in terminals and accessories for easy wiring.

Model Number Structure

Model Number Legend

1. Basic Model Name

G3RV: MOS-Solid State Relay

2. Auxiliary Type Designation

SL: Slim Solid State Relay and socket combination

3. Wire Connection

700: Screw Terminals
500: Push-in (screwless) terminals

4. Output voltage specifications

A(L): AC Output .. TRIAC

*

A: with Zero cross function  AL: without Zero cross function

D: DC Output .. MOS FET

Ordering Information

List of Models

Relay and Socket Combinations

1

2

3

4

G

3

RV-

S

@ @ @ 

@

Classification

Enclosure rating

Input voltage

Type of connection

Contact form

SPST

Plug-in terminals

General-purpose

Unsealed

AC/DC

Screw terminals

G3RV-SL700

Push-in terminals

G3RV-SL500

Input voltage

Screw terminals

Push-in terminals

12 VDC

G3RV-SL700-D 12VDC

G3RV-SL500-D 12VDC

G3RV-SL700-A(L) 12VDC

G3RV-SL500-A(L) 12VDC

24 VDC

G3RV-SL700-D 24VDC

G3RV-SL500-D 24VDC

G3RV-SL700-A(L) 24VDC

G3RV-SL500-A(L) 24VDC

24 VAC/DC

G3RV-SL700-D 24VAC/DC

G3RV-SL500-D 24VAC/DC

G3RV-SL700-A(L) 24VAC/DC

G3RV-SL500-A(L) 24VAC/DC

48 VAC/DC

G3RV-SL700-D 48VAC/DC

G3RV-SL500-D 48VAC/DC

G3RV-SL700-A(L) 48VAC/DC

G3RV-SL500-A(L) 48VAC/DC

110 VAC

G3RV-SL700-D 110VAC

G3RV-SL500-D 110VAC

G3RV-SL700-A(L) 110VAC

G3RV-SL500-A(L) 110VAC

230 VAC

G3RV-SL700-D 230VAC

G3RV-SL500-D 230VAC

G3RV-SL700-A(L) 230VAC

G3RV-SL500-A(L) 230VAC

Summary of Contents for G3RV

Page 1: ...G3RV SL Classification Enclosure rating Input voltage Type of connection Contact form SPST Plug in terminals General purpose Unsealed AC DC Screw terminals G3RV SL700 Push in terminals G3RV SL500 Inp...

Page 2: ...VDC 12 mA 21 6V 24 VAC DC 20 mA 21 mA 11 mA 21 6V 48 VAC DC 10 mA 11 mA 6 mA 43 2V 110 VAC 7 5 mA 8 2 mA 99V 230 VAC 7 3 mA 8 6 mA 207V Rated voltage Rated current Must operate voltage Must release vo...

Page 3: ...icing or condensation Operating 30 55 C with no icing or condensation Ambient humidity 45 85 RH Weight Approx 38 g Pollution degree 2 Degree of protection according to IEC 60529 IP20 Rated Impulse Wit...

Page 4: ...e Current Non repetitive Non repetitive Keep the inrush current to half the rated value if it occurs repetitively The values shown by the solid line are for non repetitive inrush currents Mounting Dis...

Page 5: ...tion Connection P2RVC 8 O F PLC Output Interface for 8x G2RV SL700 G3RV SL700 series PNP type Ribbon cable connector 10 Pole IEC603 1 Input Rated voltage 30 VAC VDC max Current capacity 0 5 A per chan...

Page 6: ...Green DC12V AC Yes 2A at 100 to 240VAC G3RV 202S DC12 G3RV SL700 500 A DC12 DC24V G3RV 202S DC24 G3RV SL700 500 A DC24 AC DC24V G3RV SL700 500 A AC DC24 AC DC48V G3RV SL700 500 A AC DC48 AC110V G3RV...

Page 7: ...minimum order Red R Blue S Black B P2RVM 030 3 60 pcs box minimum order P2RVM 040 4 60 pcs box minimum order P2RVM 100 10 20 pcs box minimum order P2RVM 200 20 20 pcs box minimum order Max current EN...

Page 8: ...n P2RV S 50 plates Provides isolation between adjacent relays to achieve 400 V isolation Five M2 5 6 6 2 max 99 2 7 1 88 9 26 1 47 2 70 9 83 106 7 max 92 7 max 35 Input circuit 24 V DC Terminal Arrang...

Page 9: ...ew Other Input Voltage Terminal Arrangement Internal Connections Top View 12 V DC Terminal Arrangement Internal Connections Top View 6 2 max 99 2 88 9 7 1 24 6 46 69 8 82 9 106 7 max 97 4 max 35 G3RV...

Page 10: ...tool Applicable Wires Applicable Wire Sizes G3RV SL700 Series Box clamp technology G3RV SL500 Series Push in technology Tightening torque G3RV SL700 Series 0 4Nm 2 5 dia 3 0 mm max Cannot be used Fla...

Page 11: ...conductor into the connection hole No other tools are required Note In case of wiring stranded wires without ferrules screwdriver should be inserted before inserting the wire Screwdriver should be re...

Page 12: ...e to connect cables properly if the screwdriver is inserted incorrectly General Precautions Do not use the product if it has been dropped on the ground Dropping the product may adversely affect perfor...

Page 13: ...Induction will be generated and cause malfunction or damages Be sure to conduct wiring with the power supply turned OFF Touching the terminals when they are charged may occationally result in minor el...

Page 14: ...ducts in the customer s application or use of the product Take all necessary steps to determine the suitability of the product for the systems machines and equipment with which it will be used Know an...

Reviews: