Precautions for Correct Use

●Installation and Storage Sites

Install and store the product in a location that meets

the following conditions:

•Surrounding temperature of 0 to +50°C(-20 to + 65°C in storage)

• No rapid changes in temperature (place where dew does not form)

• Relative humidity of between 35 to 85 %

• No presence of corrosive or flammable gases

• Place free of dust, salts and iron particles

• Place free of vibration and shock

• Place out of direct sunlight

• Place where it will not come into contact with water, oils or chemicals

●Orientation of Product

To improve heat dissipation, install the product in the

following orientation only

.

This product contains a lithium battery for which the following notice applies :Perchlorate Material - special handling may apply.

See www.dtsc.ca.gov/hazardouswaste/perchlorate

   

U.S. California Notice:

Confirming Package Contents

Ambient Temperature

• Maintain a minimum clearance of 50 mm above and below the controller 

to improve air circulation. A minimum clearance of 10 mm between 

other devices must also be maintained on the right and left sides of the 

product. However, if the adjacent devices do not generate heat, provide 

at least 50 mm of clearance from the top of the Controller. For the 

clearance at the bottom and sides, follow the mounting method.

• Do not install the product immediately above significant heat sources, 

such as heaters, transformers, or large-capacity resistors.

• Do not let the ambient temperature exceed 50 °C (122 °F).

• Provide a forced-air fan cooling or air conditioning if the ambient 

temperature is near 50 °C (122 °F) so that the ambient temperature 

never exceeds 50 °C (122 °F).

Noise Resistance

• Do not install the product in a cabinet containing high-voltage equipment.

• Do not install the product within 200 mm of power cables.

Component Installation and Handling

• Touching Signal Lines

  To prevent damage from static electricity, use a wrist strap or another 

device for preventing electrostatic discharges when touching terminals or 

signal lines in connectors.

• Handling a USB Memory

  To remove a USB memory, make sure that data is not being read or 

written to it.The LED on the USB memory flashes while data is being read 

or written, so make sure that it is lit steadily before removing the memory.

• Turning OFF the Power

  Do not turn OFF the power while a message is being displayed indicating 

that processing is being performed. Data in memory will be corrupted, and 

the product may not operate correctly the next time it is started.

• Using the RESET Signal

  Do not use the RESET input immediately after power is turned ON. When 

using the RESET input to synchronize startup timing, wait at least 15 

second after the Controller’ s power supply is turned ON before turning 

ON the RESET signal.

• The LCD panel used for the LCD-integrated type (FZ4-(H)60

(-10)/FZ4-(H)70

(-10)/FZ4-(H)110

(-10)) has been made using 

precision technology, and sometimes a few pixels are missing in the 

panel. This is due to the structure of the LCD panel, and is not a 

malfunction.

Maintenance

• Turn OFF the power and take safety precautions before conducting  

   inspections. Electrical shock can result from attempting safety   

   inspections with the power turned ON.

• Clean the lens with a lens-cleaning cloth or air brush.

• Lightly wipe off dirt with a soft cloth.

• Dirt on the CCD must be removed using an air brush.

• Do not use thinners or benzene.

Communication with High-order Device

After confirming that this product is started up, communicate with the 

high-order device.

When this product has started up, an indefinite signal may be output from 

the high-order interface.

To avoid this problem, clear the receiving buffer of your device at initial 

operations.

Applicable Wire Size: 1.31 to 2.63 mm2

Crimping Terminal

Terminal Screw: M4

8.5mm max.

8.5mm max.

Controller

・・・・・・・・・・・・・・・・

Qty.: 1

Instruction Manual

 (Japanese and English)

・・・

Qty.: 1   

Mounting bracket (for panel)

・・・・・・・・

Qty.: 6    *Supplied with the LCD integrated type onl

Touch pen

     ・・・・・・・・・・・・・・・

Qty.: 1    *Supplied with the LCD integrated type only 

Vision Sensor

Model

INSTRUCTION SHEET

Thank you for selecting OMRON product. This sheet 

primarily describes precautions required in installing and 

operating the product.

Before operating the product, read the sheet thoroughly 

to acquire sufficient knowledge of the product. For your 

convenience, keep the sheet at your disposal.

The following notice applies only to products that carry the CE mark:

Notice:

This is a class A product. In residential areas it may cause radio 

interference, in which case the user may be required to take adequate 

measures to reduce interference.

Manufacturer:

  Omron Corporation,

  Shiokoji Horikawa, Shimogyo-ku,

  

K

yoto 600-8530 J

A

PAN

TR

A

CEABILITY INFORM

A

TION:

Importer in EU:

  Omron Europe B.

V

.

  Wegalaan 67-69

  2132 JD Hoofddorp,

  The Netherlands

Meanings of Signal Words

Meanings of Alert Symbols

Alert statements in this Manual

The following alert symbols are used in this manual.

The following alert statements apply to the products in this 

manual. Each alert statement also appears at the locations 

needed in this manual to attract your attention.

Indicates a potentially hazardous 

situation which, if not avoided, will 

result in minor or moderate injury, or 

may result in serious injury or death. 

Additionally there may be significant 

property damage.

WARNING

Indicates a potentially hazardous 

situation which, if not avoided, may 

result in minor or moderate injury or in 

property damage.

Indicates general prohibitions for which there is 

no specific symbol.
Indicates the possibility of electric shock under 

specific conditions.
Indicates the possibility of explosion under 

specific conditions.

Indicates the possibility of laser radiation.
Indicates the possibility of injury by high 

temperature under specific conditions.

CAUTION

Symbols and the meanings for safety precautions 

described in this manual.

In order for the product to be used safely, the following indications are 

used in this book to draw your attention to the cautions. The cautions 

with the indications describe the important contents for safety.

CAUTION

Danger of burns. Do not touch the case while the 

LED is ON or just after power is turned OFF, 

since it remains extremely hot.

Precautions for Safe Use

• Keep the power supply wires as short as possible

(Max.10m).

• Use a DC power supply with safety measures against high-voltage 

spikes(safety extra low-voltage circuits on the secondary side).

Ground the product's ground terminal to less than 100Ω.

Use a grounding point that is as close as possible and keep the 

ground wire as short as possible.

Wire the Controller to the ground with a separate ground wire. To 

avoid grounding problems, do not share the ground wire with any 

other devices or wire the ground to the building's steel framing.

• Do the following confirmations again before turning on the 

power supply. 

 - Is the voltage of the power supply correct? (24VDC)

 - Is not the load of the output signal short-circuited?

 - Is the load current of the output signal appropriate?

 - Is not the mistake found in wiring?

Installation Environment

• Do not use the product in areas where flammable or explosive 

gases are present.

• Install the product so that air can flow freely through its cooling 

vents.

• Do not install the product close to high-voltage devices and power 

devices in order to secure the safety of operation and 

maintenance.

• Make sure to tighten all installation screws securely.

Power Supply and Wiring

• Make sure to use the product with the power supply voltage 

specified by this manual.

• Use the cables and crimping terminals with the specified 

dimensions. Do not directly connect an electric wire to the terminal 

block that is simply twisted.

●Ground

The controller power circuit is not insulated from its internal circuit.

When grounding the positive terminal of the 24 V DC power supply, 

do not ground the controller s FG terminal, the PLC s FG terminal, or 

EtherCAT facing component s FG terminal. 

【①

,

,

③】

   Since the PC s shell and the SG (0V) are connected inside the PC, 

current would run through the route shown in the figure below and 

cause burnout. 

As in the case with a PC, you can safely ground the controller s FG 

terminal without a problem when there is no possibility that the SG 

(0V) and the FG will short-circuit. For information about the PLC 

wiring, check the specifications of your PLC before wiring. 

Be sure to use a pedestal when connecting a camera to the 

controller.

【④】

   As the shell of the camera is the SG (0V), it can cause 

short-circuiting between the SG (0V) and the FG if a pedestal is not 

used.

To avoid receiving an electric shock when grounding

 a positive terminal, do not touch the SG (0V)

 (camera, power supply terminal).

When mounting a box-shaped controller (FZ4-(H)65

(-10)/FZ4-(H)75

(-10)/FZ4-(H)115

(-10)) at its base, it will 

short-circuit to the FG of

 

your device since the bottom surface is 

connected to the SG (0V). In order to avoid this, we provide

   insulating spacers. Please consult your OMRON representative for 

information.

Other

• Use only the camera and cables designed specifically for the product. 

Use of other products may result in malfunction or damage of the 

product.

• Always turn OFF the Controller's power before connecting or 

disconnecting a camera or cable. Connecting the cable with power 

supplied may result in damage of the camera or peripheral devices.

• Do not attempt to dismantle, repair, or modify the product.

• Should you notice any abnormalities, immediately stop use, turn OFF 

the power supply, and contact your OMRON representative.

• Do not touch fluorescent or halogen lights while the power is ON or 

immediately after the power is tumed OFF.

• Dispose of this product as industrial waste.

WARNING

This product must be used according to the 

instruction manual. Failure to observe this may 

result in impairment of functions and 

performance of the product.
This product is not designed or rated for 

ensuring safety of persons. Do not use it for 

such purposes.
Never connect the AC power supply with this

product. When the AC power supply is

connected, it causes the electric shock and a fire.
A lithium battery is built into the Controller and 

may occasionally combust, explode, or burn if 

not treated properly. Dispose of the Controller as 

industrial waste, and never disassemble, apply 

pressure that would deform, heat to 100

 or 

higher, or incinerate the Controller.
Since camera that can be connected with this 

product emits a visible light that may have an 

adverse effect on the eyes, do not stare directly 

into the light emitted from the LED. If a specular 

object is used, take care not to allow reflected 

light enter your eyes.

Please take external safety measures so that the system 

as a whole should be on the safe side even if a failure of 

a sensor controller or an error due to an external factor 

occurred.An abnormal operation may result in a serious 

accident.
Please take fail-safe measures on your side in 

preparation for an abnormal signal due to signal 

conductor disconnection and/or momentary power 

interruption.An abnormal operation may result in a 

serious accident.

Regulations of KC marking

A급 기기(업무용 방송통신기자재)

이 기기는 업무용(A급) 전자파적합기기로서 판매자

또는 사용자는 이 점을 주의하시기 바라며,가정외의

지역에서 사용하는 것을 목적으로 합니다.

1

2

3

4

SG(0V)

0V

SG(0V)

SG

SG

24V

SG

SG

FG

FG

FG

RS-232C

SG

SG

SG FG

FG

PLC

FG

FG

FG

SG:

FG:

Signal Ground

Frame Ground

EtherCAT 

connector's 

shell

EtherCAT 

facing component

Camera

Shell

Controller

Camera cable

Parallel I/O 

connector’s 

shell

RS-232C 

connector’s shell

Mounting spacer 

(insulator)

Power 

supply

Power supply 

circuit

Do not install in this orientation.

LCD integrated type

Do not install in this orientation.

Box type

To reserve ventilation path, 

the feet must be mounted 

to the side panel that is 

positioned at the base.

 

 

(provided inside the controller).

* Items indicated with an asterisk are dedicated items, and cannot be substituted.

Camera

LCD monitor

FZ-M08 (8.4-inch)

FZ-VM (2 m, 5 m)

Camera cable

FZ-VS3 (2 m, 3m, 5 m, 10 m)

Box type

FZ4-(H)65□(-10)

FZ4-(H)75□(-10)

FZ4-

H)115□(-10)

LCD integrated type

FZ4-(H)60□(-10)

FZ4-(H)70□(-10)

FZ4-(H)110□(-10)

Front view

Touch pen (standard accessory)

Right-side view

Controller

*

Monitor cable

Controller

*

*

Camera cable

*

*

*

Bend resistant camera cable

FZ-VSB3 (2 m, 3m,  5 m, 10 m)
Right-angle camera cable

FZ-VSL3 (2 m, 3m,  5 m, 10 m)
Bend resistant 

Right-angle camera cable

FZ-VSLB3 (2 m, 3m,  5 m, 10 m)
Long-distance camera cable

FZ-VS4 (15m)
Long-distance Right-angle 

camera cable

FZ-VSL4 (15m)

Power Supply

Recommended Model

   By OMRON Corporation

   S8VS-12024

Detects workpieces as images.

Basic Configuration

Peripheral Device

Input Device

USB memory

FZ-MEM2G/FZ-MEM8G

Mouse, track ball

(Commercially available 

USB devices)

Standalone camera

FZ-SC/FZ-S/FZ-SC2M

FZ-S2M

FZ-SC5M2/FZ-S5M2/FZ-SFC

FZ-SF/FZ-SPC/FZ-SP

FZ-SHC/FZ-SH

Use the monitor to check images and display the 

condition-setting menus. The Controller performs 

the image processing specified by the user settings 

and outputs the measurement results.

The Controller performs the image 

processing specified by the user settings 

and outputs the measurement results.

Use the monitor to check images 

and display the condition-setting 

menus.

* FZ-SC5M2 and FZ-S5M2 can be connected to FZ4-6

□□

 and FZ4-H6

□□

/

FZ4-7

□□

/FZ4-H7

□□

/FZ4-11

□□

/FZ4-H11

□□

.

* Intelligent compact camera can be connected to FZ4-6

□□

 and FZ4-H6

□□

/FZ4-7

□□

/FZ4-H7

□□

/

FZ4-11

□□

/FZ4-H11

□□

.

Intelligent compact camera

FZ-SQ010F/FZ-SQ050F

FZ-SQ100F/FZ-SQ100N

Camera connector

Ethernet connector

Monitor connector 

(analog RGB)

USB connector

RS-232C/RS-422 

connector

I/O connector 

(control lines, data lines)

Front view

Left-side view

Right-side view

Power/

ground terminal

POWER LED

RUN LED

ERROR LED

USB connector

Touch pen (holder)

Component Names and Functions

6 7

1
2
3

10

4

5

8

9

10

11

12

LCD integrated type    

FZ4-(H)60□(-10)/FZ4-(H)70□(-10)/FZ4-(H)110□(-10)