P/N 18982-008 Rev A FLOW Service Guide
12
5. Replacing a failed EM1100
Step
Check Item
Task to be Performed
Check
1
Remove EM1100
from rack
If installed in a rack, remove the EM1100 from the rack. To do this pull the EM1100 until it is
fully extended from the track. Press the locking bottons on the side of the rail and continue to
pull until EM comes out of the rack. Remove the rails from the EM1100 and install on the
EM2100. See the EM2100 installation guide for how to install the EM2100 into the rack.
Note:
The EM2100 is 3.4 inches longer, however, in most instances identical mounting can be used.
□
2
Configure EM2100 Follow the procedure in the FLOW Core User
’
s Guide for setting up EM2100
□
3
Downgrade Moblile
Software Suite to
4.9.27A
If the fleet is running a version of Mobile Software Suite (MSS) 4.X, follow the procedure in
the FLOW Migration Guide for downgrading from FLOW Core to the MSS version the fleet
is using.
Note:
This step is only necessary if you are downgrading from FLOW Core to a
version of MSS 4.X.